Adverse surface interactions between one-bottle light-cured adhesives and chemical-cured composites

Anna Marie E. Sanares, Anut Itthagarun, Nigel M. King, Franklin R. Tay, David H. Pashley

Research output: Contribution to journalArticlepeer-review

248 Scopus citations

Abstract

Objectives: This study examined the effect of one-bottle adhesives with different acidities on bonding to chemical-cured and light-cured resin composites. Methods: Twenty-four non-carious human third molars were divided into eight groups. A flat dentin surface was created for each tooth. Acid-conditioned dentin surfaces were bonded with Prime&Bond NT (Dentsply), OptiBond SOLO (Kerr), Single Bond (3M) or One-Step (Bisco). Each adhesive group was covered with composite buildups, using either a light-cured (Z100, 3M) or a chemical-cured composite (BisFil 2, Bisco). Specimens were vertically sectioned into 0.9 × 0.9 mm beams. Microtensile bond strengths were recorded and failure modes were classified using a stereoscopical microscope. Four representative beams from each group were further prepared for SEM examination. Results: Two-way ANOVA showed that the effect of adhesive types, composite curing modes and their interaction were statistically significant (P < 0.001). Multiple comparison tests revealed no statistically significant difference in the bond strength of the four adhesives with the light-cured composite (P > 0.05). However, they were significantly lower when used with the chemical-cured composite (P < 0.01). A positive correlation was observed between the acidity of adhesives and the bond strengths of the chemical-cured composite. Failure occurred predominantly along the composite-adhesive interface, with microporosities on the adhesive surface and voids within the chemical-cured composite. Significance: Air incorporated during mixing of chemical-cured composites only contributed partially to the decreased bond strength observed in simplified-step adhesives. Ultrastructural observations suggested the presence of a surface interaction between the uncured, acidic resin monomers from the oxygen inhibition layer of the adhesive and the initiator components in the chemical-cured composite.

Original languageEnglish (US)
Pages (from-to)542-556
Number of pages15
JournalDental Materials
Volume17
Issue number6
DOIs
StatePublished - Nov 2001

Keywords

  • Acidity
  • Chemical-cured composites
  • Light-cured composites
  • Microtensile bond strength
  • One-bottle adhesives
  • SEM

ASJC Scopus subject areas

  • General Materials Science
  • General Dentistry
  • Mechanics of Materials

Fingerprint

Dive into the research topics of 'Adverse surface interactions between one-bottle light-cured adhesives and chemical-cured composites'. Together they form a unique fingerprint.

Cite this