N2 - It is widely recommended that hemodialysis graft surveillance programs should be implemented and that significant stenosis should be corrected when it is accompanied by graft dysfunction. The rationale for surveillance depends on the dysfunction hypothesis, which states that stenosis causes graft dysfunction [such as a decrease in graft blood flow (Qa)], and this dysfunction reliably precedes and accurately predicts thrombosis. The usefulness of Qa surveillance depends on accurate prediction of thrombosis so that stenosis can be corrected prior to thrombosis. An analysis of the dysfunction hypothesis indicates that some or all of its underlying assumptions are invalid. Most importantly, the presence of wide hemodynamic variation during Qa measurements makes Qa a relatively inaccurate predictor of throm-bosis. A number of studies have evaluated the value of surveillance with intervention in reducing thrombosis rates and prolonging graft life. Review of these studies show that few have been prospective and randomized, and many have included historical control groups. It is debatable whether these studies have established that Qa surveillance with intervention should be applied to all grafts. Data from several studies suggest that severity of stenosis may be at least as accurate as Qa in predicting thrombosis. Consequently, inclusion of stenosis measurements (e.g., by duplex ultrasound) may improve the results of surveillance. These unresolved issues indicate it is premature to recommend routine Qa surveillance with intervention of all hemodialysis patients with grafts.
AB - It is widely recommended that hemodialysis graft surveillance programs should be implemented and that significant stenosis should be corrected when it is accompanied by graft dysfunction. The rationale for surveillance depends on the dysfunction hypothesis, which states that stenosis causes graft dysfunction [such as a decrease in graft blood flow (Qa)], and this dysfunction reliably precedes and accurately predicts thrombosis. The usefulness of Qa surveillance depends on accurate prediction of thrombosis so that stenosis can be corrected prior to thrombosis. An analysis of the dysfunction hypothesis indicates that some or all of its underlying assumptions are invalid. Most importantly, the presence of wide hemodynamic variation during Qa measurements makes Qa a relatively inaccurate predictor of throm-bosis. A number of studies have evaluated the value of surveillance with intervention in reducing thrombosis rates and prolonging graft life. Review of these studies show that few have been prospective and randomized, and many have included historical control groups. It is debatable whether these studies have established that Qa surveillance with intervention should be applied to all grafts. Data from several studies suggest that severity of stenosis may be at least as accurate as Qa in predicting thrombosis. Consequently, inclusion of stenosis measurements (e.g., by duplex ultrasound) may improve the results of surveillance. These unresolved issues indicate it is premature to recommend routine Qa surveillance with intervention of all hemodialysis patients with grafts.
UR - http://www.scopus.com/inward/record.url?scp=0035346324&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035346324&partnerID=8YFLogxK
U2 - 10.1046/j.1525-139X.2001.00049.x
DO - 10.1046/j.1525-139X.2001.00049.x
M3 - Article
C2 - 11422923
AN - SCOPUS:0035346324
SN - 0894-0959
VL - 14
SP - 175
EP - 180
JO - Seminars in Dialysis
JF - Seminars in Dialysis
IS - 3
ER -