Skip to main navigation Skip to search Skip to main content

Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems

Research output: Contribution to journalArticlepeer-review

Abstract

Introduction: Recent innovative manufacturing techniques have produced nickel-titanium (NiTi) rotary instruments with reports of superior properties compared with standard NiTi files. These include Profile Vortex made from M-Wire (PV), Twisted Files (TF), and 10 Series files made from CM Wire (CM). Sterilization is recommended before use and is repeated if files are reused and/or carried forward between cases. The purpose for this study was to compare the effects of multiple autoclaving cycles on the torsional load resistance of these 3 new rotary endodontic files. Methods: PV, TF, and CM files (n = 100; size 25/.04) were divided into 5 groups (n = 20). Files were steam autoclaved for 1, 2, 3, and 7 sterilization cycles. A control group was not subjected to autoclaving. Files were tested in a torsiometer in general accordance with ISO 3630-1 standards. Torsional load and degrees of rotation to failure were recorded. Mean data were analyzed by using Kruskal-Wallace/Dunn post hoc tests (P <.05). Results: Autoclave cycles had no significant overall effect on file performance for any of the instrument systems tested. PV and CM displayed significantly greater resistance to torsional load than TF (P <.001) but were not different from each other (P >.05). Angular deflection values for TF and CM were significantly higher than for PV (P <.001), with TF demonstrating greater rotational distortion than CM (P <.05). Conclusions: Under the conditions of this study, repeated steam autoclaving did not affect torsional resistance for unused files of the systems evaluated. In addition, CM Wire files might have a combined advantage of greater torsional strength and high deformation before failure.

Original languageEnglish (US)
Pages (from-to)1572-1575
Number of pages4
JournalJournal of endodontics
Volume37
Issue number11
DOIs
StatePublished - Nov 2011
Externally publishedYes

Keywords

  • Controlled memory-wire
  • Twisted File
  • memory wire
  • nickle-titanium

ASJC Scopus subject areas

  • General Dentistry

Fingerprint

Dive into the research topics of 'Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems'. Together they form a unique fingerprint.

Cite this