Confirmation of pulmonary vein isolation with high-density mapping: Comparison to traditional workflows

Christopher Porterfield, Peter J. Gora, Alexander Wystrach, Pietro Rossi, Mariano Rillo, Frederic A. Sebag, Marco Giuggia, Massimo Mantica, Anja Dorszewski, Zayd Eldadah, Mario Volpicelli, Nicola Bottoni, Christian Jøns, Zachary T. Hollis, Lukas Dekker, Shibu Mathew, Joern Schmitt, Kent Nilsson

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Yet tools and techniques used for confirmation of PVI vary greatly, and it is unclear whether the use of any particular combination of tools and techniques provides greater sensitivity for identifying gaps periprocedurally. It has been suggested that the use of a high-density mapping catheter, which enables simultaneous recording of adjacent bipolar EGMs in two directions, may provide improved sensitivity for gap identification. Anonymized, acute procedural data was prospectively collected in AF ablation cases utilizing various workflows for confirmation of PVI. Post-hoc analysis was performed to evaluate the incidence of gaps detected by different diagnostic catheter technologies, including a high-density mapping catheter and circular mapping catheters (CMCs), and common techniques such as pacing the ablation lines. A total of 139 cases were included across three subgroup analyses: 99 cases were included in an indirect comparison of three mapping catheter technologies, revealing gaps in 36.7%, 38.9%, and 81.8% of cases utilizing a 10-pole CMC, 20-pole CMC, and a high-density mapping catheter, respectively; a direct comparison of diagnostic catheter technologies in 18 cryoballoon ablation cases revealed residual gaps in 22.2% of patients identified by high-density mapping which were missed previously with the use of a 3.3F CMC; in 22 cases utilizing a technique of pacing the ablation lines, high-density mapping identified residual gaps in 68.2% of patients. This proof of concept analysis demonstrated that the use of a high-density catheter which records orthogonal bipoles simultaneously, appears to improve acute detection of gaps in PVI lines relative to other commonly utilized techniques and technologies. The long-term impact of ablating these concealed gaps remains unclear. Further study, including direct comparison of diagnostic catheter technologies in a randomized setting with long-term followup, is warranted.

Original languageEnglish (US)
JournalJournal of Atrial Fibrillation
Volume12
Issue number6
DOIs
StatePublished - May 2020
Externally publishedYes

Keywords

  • Atrial Fibrillation
  • High density mapping
  • Pulmonary vein isolation (PVI)

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Confirmation of pulmonary vein isolation with high-density mapping: Comparison to traditional workflows'. Together they form a unique fingerprint.

Cite this