N2 - Objectives To examine the effects of composite type (bulk-fill/ conventional) and placement (4-mm bulk/2-mm increments) on internal marginal adaptation of Class I preparations. Methods Cylindrical, Class I, 4-mm × 4-mm preparations were made on 50 recently extracted human molars and restored using either a bulk-fill (SureFil SDR Flow (SDR), Quixx (QX), SonicFill (SF), Tetric EvoCeram Bulk (TEC)) or a conventional composite designed for 2-mm increments (Filtek Supreme Ultra (FSU)). Restorations were placed in 1 or 2 increments using the manufacturer's bonding agent and curing light (n = 5). Teeth were sectioned occluso-gingivally and dye was placed on the internal margin and visually examined by 3 observers. Gap-free marginal lengths were analysed within three different regions of the sectioned tooth: enamel, mid-dentine, and pulpal floor. Results Marginal integrity was unaffected by placement method. Bulk-placement demonstrated significantly fewer gap-free margins at the pulpal floor than in enamel, for all materials except SDR. Greater percentages of gap-free margins were found within the mid-dentine than at the pulpal floor for FSU. QX had more gap-free margins in enamel compared with the mid-dentine. Proportion of gap-free margins within enamel and mid-dentine was not significantly different for any incrementally placed product. Excluding FSU, gap-free margins within enamel were significantly greater than at the pulpal floor. Notably, significantly more gap-free margins were found within mid-dentine than at the pulpal floor for SF. Conclusions No significant differences in gap-free margins were found between placement methods within a given product per location. Except for SDR, percentage of gap-free margins was significantly lower at the pulpal floor interface than at the enamel interface for bulk-fill.
AB - Objectives To examine the effects of composite type (bulk-fill/ conventional) and placement (4-mm bulk/2-mm increments) on internal marginal adaptation of Class I preparations. Methods Cylindrical, Class I, 4-mm × 4-mm preparations were made on 50 recently extracted human molars and restored using either a bulk-fill (SureFil SDR Flow (SDR), Quixx (QX), SonicFill (SF), Tetric EvoCeram Bulk (TEC)) or a conventional composite designed for 2-mm increments (Filtek Supreme Ultra (FSU)). Restorations were placed in 1 or 2 increments using the manufacturer's bonding agent and curing light (n = 5). Teeth were sectioned occluso-gingivally and dye was placed on the internal margin and visually examined by 3 observers. Gap-free marginal lengths were analysed within three different regions of the sectioned tooth: enamel, mid-dentine, and pulpal floor. Results Marginal integrity was unaffected by placement method. Bulk-placement demonstrated significantly fewer gap-free margins at the pulpal floor than in enamel, for all materials except SDR. Greater percentages of gap-free margins were found within the mid-dentine than at the pulpal floor for FSU. QX had more gap-free margins in enamel compared with the mid-dentine. Proportion of gap-free margins within enamel and mid-dentine was not significantly different for any incrementally placed product. Excluding FSU, gap-free margins within enamel were significantly greater than at the pulpal floor. Notably, significantly more gap-free margins were found within mid-dentine than at the pulpal floor for SF. Conclusions No significant differences in gap-free margins were found between placement methods within a given product per location. Except for SDR, percentage of gap-free margins was significantly lower at the pulpal floor interface than at the enamel interface for bulk-fill.
KW - Bulk-fill
KW - Composites
KW - Margin adaptation
UR - http://www.scopus.com/inward/record.url?scp=84897081149&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84897081149&partnerID=8YFLogxK
U2 - 10.1016/j.jdent.2014.01.005
DO - 10.1016/j.jdent.2014.01.005
M3 - Article
C2 - 24480086
AN - SCOPUS:84897081149
SN - 0300-5712
VL - 42
SP - 439
EP - 449
JO - Journal of Dentistry
JF - Journal of Dentistry
IS - 4
ER -