Abstract
Abstract. Four methods were investigated to determine their suitability as platelet compatibility procedures: leukoagglutination, lymphocytotoxicity, platelet suspension immunofluorescence and platelet enzyme‐linked immunosorbant assay. None of the tests were found to reliably predict the 24‐hour‐posttransfusion platelet increment in 8 refractory thrombocytopenic patients judged refractory to random donor platelet therapy.
Original language | English (US) |
---|---|
Pages (from-to) | 247-252 |
Number of pages | 6 |
Journal | Vox Sanguinis |
Volume | 40 |
Issue number | 4 |
DOIs | |
State | Published - Apr 1981 |
ASJC Scopus subject areas
- Hematology