Abstract
Abstract. Four methods were investigated to determine their suitability as platelet compatibility procedures: leukoagglutination, lymphocytotoxicity, platelet suspension immunofluorescence and platelet enzyme‐linked immunosorbant assay. None of the tests were found to reliably predict the 24‐hour‐posttransfusion platelet increment in 8 refractory thrombocytopenic patients judged refractory to random donor platelet therapy.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 247-252 |
| Number of pages | 6 |
| Journal | Vox Sanguinis |
| Volume | 40 |
| Issue number | 4 |
| DOIs | |
| State | Published - Apr 1981 |
| Externally published | Yes |