TY - JOUR
T1 - Mass loss in urethane/TEGDMA- and Bis-GMA/TEGDMA-based resin composites during post-cure heating.
AU - Bagis, Y. H.
AU - Rueggeberg, F. A.
N1 - Copyright:
This record is sourced from MEDLINE/PubMed, a database of the U.S. National Library of Medicine
PY - 1997/11
Y1 - 1997/11
N2 - OBJECTIVES: This research examined weight loss of commercial UDMA/TEGDMA- and Bis-GMA/TEGDMA-based resin composites at a variety of post-cure temperatures. Weight loss profiles of individual monomer components were also tested at elevated temperature: Bis-GMA, ethoxylated Bis-GMA (EBis-GMA), urethane dimethacrylate (UDMA), and triethyleneglycol dimethacrylate (TEGDMA). METHODS: Disc-shaped composite specimens (1 x 5 mm, approximately 50 mg) were light-cured and then isothermally post-cure heated in a thermogravimetric analysis (TGA) unit at either 50 degrees, 75 degrees, 100 degrees, 125 degrees or 150 degrees C. A single specimen was made for each post-cure temperature for each product (a total of 10 discs). Individual monomer components were heated to 800 degrees C. Filler and organic phase weight percentages were determined by ashing cured composite in the TGA. Weight loss differences between resin systems at various post-cure temperatures were analyzed using linear regression. RESULTS: For each type of composite, loss of volatile component increased with both elevated post-cure temperature as well as duration of heat exposure. Using recommended post-cure temperature and time (125 degrees C for 7.5 minutes), there was no difference in weight loss profile between the two products: both exhibited 1.3% loss of resin component. After 10 min of heating, the Bis-GMA-based product always demonstrated a greater weight loss than the UDMA material. Weight loss could not be attributed to any specific monomer. SIGNIFICANCE: Specimen weight loss during post-cure heating may result in a depletion of leachable, unreacted material at the restoration surface, possibly enhancing material properties at that location. This decrease would also potentially reduce the biological impact of leachable materials. Loss of volatile components from post-cure heating would affect the accuracy of infrared spectroscopic techniques in determining monomer conversion values.
AB - OBJECTIVES: This research examined weight loss of commercial UDMA/TEGDMA- and Bis-GMA/TEGDMA-based resin composites at a variety of post-cure temperatures. Weight loss profiles of individual monomer components were also tested at elevated temperature: Bis-GMA, ethoxylated Bis-GMA (EBis-GMA), urethane dimethacrylate (UDMA), and triethyleneglycol dimethacrylate (TEGDMA). METHODS: Disc-shaped composite specimens (1 x 5 mm, approximately 50 mg) were light-cured and then isothermally post-cure heated in a thermogravimetric analysis (TGA) unit at either 50 degrees, 75 degrees, 100 degrees, 125 degrees or 150 degrees C. A single specimen was made for each post-cure temperature for each product (a total of 10 discs). Individual monomer components were heated to 800 degrees C. Filler and organic phase weight percentages were determined by ashing cured composite in the TGA. Weight loss differences between resin systems at various post-cure temperatures were analyzed using linear regression. RESULTS: For each type of composite, loss of volatile component increased with both elevated post-cure temperature as well as duration of heat exposure. Using recommended post-cure temperature and time (125 degrees C for 7.5 minutes), there was no difference in weight loss profile between the two products: both exhibited 1.3% loss of resin component. After 10 min of heating, the Bis-GMA-based product always demonstrated a greater weight loss than the UDMA material. Weight loss could not be attributed to any specific monomer. SIGNIFICANCE: Specimen weight loss during post-cure heating may result in a depletion of leachable, unreacted material at the restoration surface, possibly enhancing material properties at that location. This decrease would also potentially reduce the biological impact of leachable materials. Loss of volatile components from post-cure heating would affect the accuracy of infrared spectroscopic techniques in determining monomer conversion values.
UR - http://www.scopus.com/inward/record.url?scp=0031282689&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031282689&partnerID=8YFLogxK
U2 - 10.1016/s0109-5641(97)80110-8
DO - 10.1016/s0109-5641(97)80110-8
M3 - Article
C2 - 9823100
AN - SCOPUS:0031282689
SN - 0109-5641
VL - 13
SP - 377
EP - 380
JO - Dental materials : official publication of the Academy of Dental Materials
JF - Dental materials : official publication of the Academy of Dental Materials
IS - 6
ER -