Skip to main navigation Skip to search Skip to main content

Microtensile bond strength of adhesive systems to dentin with or without application of an intermediate flowable resin layer

  • Mario Fernando de Goes
  • , Marcelo Giannini
  • , Vinícius di Hipólito
  • , Marcela Rocha de Oliveira Carrilho
  • , Márcia Daronch
  • , Frederick Rueggeberg

Research output: Contribution to journalArticlepeer-review

Abstract

This study evaluated the effect of flowable composite resin application on the microtensile bond strength μ TBS) of adhesive systems to dentin. Occlusal surfaces of human third molars were ground to obtain flat dentin surfaces. The crown of each tooth was sectioned occluso-gingivally into four quarters with a water-cooled diamond saw. One of the following adhesive systems was applied to dentin surface in each quarter of the same tooth, following manufacturers' instructions: Scotchbond Multipurpose, Single Bond Adper Prompt and Clearfil SE Bond. Experimental and control groups received the same treatment, except for the fact that a layer of flowable composite (Filtek Flow) was placed and light-cured on top of the adhesive layer in the specimens of the experimental groups. Resin composite (Filtek Z250) crown buildups were then made on the bonded surfaces and incrementally light-cured for 20 s. The restored teeth were stored in water at 37oC for 24 h. Each tooth quarter was serially cut in a longitudinal direction in order to obtain several bonded sticks (0.9-mm2 in cross-section). Maximal microtensile stress (in MPa) at failure was recorded using a universal testing machine. Data were analyzed by two-way ANOVA and Tukey's test at 5% significance level. Placement of a low-viscosity resin to the hybridized dentin increased the μTBS for all tested adhesive systems. However, such increase was significant only for Clearfil SE Bond (p<0.05). When the restorations were placed without low-viscosity resin, Clearfil SE Bond presented higher μTBS than Adper Prompt (p<0.05). For the groups treated with flowable composite, Clearfil SE Bond produced the highest μ TBS means to dentin. In conclusion, the effect of the addition of an intermediate flowable composite layer on μ TBS to dentin was material-dependent and resulted in an increased adhesion for all tested materials, though with significance only for Clearfil SE Bond.

Original languageEnglish (US)
Pages (from-to)51-56
Number of pages6
JournalBrazilian dental journal
Volume19
Issue number1
DOIs
StatePublished - 2008

Keywords

  • Adhesive system
  • Bond strength
  • Composite resin
  • Dentin

ASJC Scopus subject areas

  • General Dentistry

Fingerprint

Dive into the research topics of 'Microtensile bond strength of adhesive systems to dentin with or without application of an intermediate flowable resin layer'. Together they form a unique fingerprint.

Cite this