Outcomes following routine antithrombin III replacement during neonatal extracorporeal membrane oxygenation

Brian K. Stansfield, Linda Wise, P. Benson Ham, Pinkal Patel, Malinda Parman, Chan Jin, Sunil Mathur, Gregory Harshfield, Jatinder Bhatia

Research output: Contribution to journalArticlepeer-review

38 Scopus citations

Abstract

BACKGROUND: We sought to examine the effect of routine antithrombin III (AT3) infusion on hemorrhagic and thrombotic complications, blood product utilization, and circuit lifespan in neonatal extracorporeal membrane oxygenation (ECMO).

METHODS: We performed a retrospective cohort study of 162 infants placed on ECMO for hypoxic respiratory failure. Infants requiring ECMO for primary cardiac support were excluded. Demographic data, time on ECMO, blood product usage, coagulation profile, and complications were compared between 90 control patients and 72 patients treated with AT3.

RESULTS: Infants receiving AT3 during ECMO had less thrombotic and similar bleeding complications as compared to infants receiving standard anticoagulation therapy. Total blood product infusion during ECMO was decreased (54.7±20.1 vs. 67.4±34.9mL/kg per day, p=0.001) in infants receiving AT3 during ECMO. Tighter control of activated clotting time and higher serum heparin anti-Xa levels were observed in the AT3 cohort during the first days of ECMO support. 1st ECMO circuit lifespan did not differ between groups.

CONCLUSIONS: Routine administration of AT3 in neonates receiving ECMO therapy was associated with tighter control of anticoagulation and a reduction in thrombotic events without increasing unwanted bleeding. However, circuit lifespan was unaffected.

LEVEL OF EVIDENCE: Level III.

Original languageEnglish (US)
JournalJournal of Pediatric Surgery
DOIs
StatePublished - Oct 30 2016

Keywords

  • Antithrombin III
  • Bleeding
  • Coagulation
  • ECMO
  • Neonatal
  • Thrombosis

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Surgery

Fingerprint

Dive into the research topics of 'Outcomes following routine antithrombin III replacement during neonatal extracorporeal membrane oxygenation'. Together they form a unique fingerprint.

Cite this