Y1 - 2019/4
N2 - BACKGROUND: The reported ventricular assist device (VAD) experience in the pediatric congenital heart disease (CHD) population is limited. We sought to describe contemporary use and outcomes of VADs in children with CHD and compare these outcomes to those of non-CHD children. METHODS: Patients enrolled in the Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) between September 19, 2012 through June 30, 2017 were included. CHD was classified as biventricular vs single ventricle (Stages 1, 2, or 3). Outcomes were compared between groups and multivariable analysis was used to identify factors associated with mortality on the device. RESULTS: Among the 471 patients enrolled, 108 (24%) had CHD (45 biventricular and 63 single ventricle). CHD patients were younger (5.7 ± 5.7 years vs 9.8 ± 6.5 years; p < 0.0001) and smaller (0.8 ± 0.5 m2 vs 1.2 ± 0.7 m2; p < 0.0001) compared with non-CHD patients. CHD patients were more likely to receive a paracorporeal continuous-flow VAD (36.1% vs 12.9%; p < 0.0001) and less likely to receive an implantable continuous-flow VAD (27.8% vs 55.0%; p < 0.0001) compared with non-CHD patients. After 6 months on a VAD, CHD patients had higher mortality (36.4% vs 12.1%) and a lower transplantation rate (29.1% vs 59.9%) than non-CHD patients (p < 0.0001). In the multivariable analysis, CHD was the factor most strongly associated with mortality on VAD (hazard ratio [HR] = 2.9; p < 0.0001), whereas the factors implantable continuous-flow device and high-volume center were protective (HR = 0.3, p < 0.0001, and HR = 0.6, respectively; p = 0.02). CONCLUSIONS: VAD use in children with CHD is associated with increased mortality and decreased transplant rates compared to children without CHD. For the subgroup of children with CHD who received implantable continuous-flow VADs, survival rates were higher and comparable to those of children without CHD. Increased experience correlated with better survival in pediatric VADs.
AB - BACKGROUND: The reported ventricular assist device (VAD) experience in the pediatric congenital heart disease (CHD) population is limited. We sought to describe contemporary use and outcomes of VADs in children with CHD and compare these outcomes to those of non-CHD children. METHODS: Patients enrolled in the Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) between September 19, 2012 through June 30, 2017 were included. CHD was classified as biventricular vs single ventricle (Stages 1, 2, or 3). Outcomes were compared between groups and multivariable analysis was used to identify factors associated with mortality on the device. RESULTS: Among the 471 patients enrolled, 108 (24%) had CHD (45 biventricular and 63 single ventricle). CHD patients were younger (5.7 ± 5.7 years vs 9.8 ± 6.5 years; p < 0.0001) and smaller (0.8 ± 0.5 m2 vs 1.2 ± 0.7 m2; p < 0.0001) compared with non-CHD patients. CHD patients were more likely to receive a paracorporeal continuous-flow VAD (36.1% vs 12.9%; p < 0.0001) and less likely to receive an implantable continuous-flow VAD (27.8% vs 55.0%; p < 0.0001) compared with non-CHD patients. After 6 months on a VAD, CHD patients had higher mortality (36.4% vs 12.1%) and a lower transplantation rate (29.1% vs 59.9%) than non-CHD patients (p < 0.0001). In the multivariable analysis, CHD was the factor most strongly associated with mortality on VAD (hazard ratio [HR] = 2.9; p < 0.0001), whereas the factors implantable continuous-flow device and high-volume center were protective (HR = 0.3, p < 0.0001, and HR = 0.6, respectively; p = 0.02). CONCLUSIONS: VAD use in children with CHD is associated with increased mortality and decreased transplant rates compared to children without CHD. For the subgroup of children with CHD who received implantable continuous-flow VADs, survival rates were higher and comparable to those of children without CHD. Increased experience correlated with better survival in pediatric VADs.
KW - congenital heart disease
KW - heart failure
KW - heart transplantation
KW - outcomes
KW - pediatric heart failure
KW - pediatric heart transplantation
KW - pediatrics
KW - ventricular assist device
UR - http://www.scopus.com/inward/record.url?scp=85056589601&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056589601&partnerID=8YFLogxK
U2 - 10.1016/j.healun.2018.10.008
DO - 10.1016/j.healun.2018.10.008
M3 - Article
C2 - 30459063
AN - SCOPUS:85056589601
SN - 1053-2498
VL - 38
SP - 420
EP - 430
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 4
ER -