TY - JOUR
T1 - Securing extraocular muscles in strabismus surgery
T2 - laboratory analysis of biomechanical parameters related to the suture
AU - Brooks, Steven E.
N1 - Funding Information:
Funding support: unrestricted grant from Research to Prevent Blindness Inc and the Jonas Family Fund.
Publisher Copyright:
© 2017 American Association for Pediatric Ophthalmology and Strabismus
PY - 2017/12
Y1 - 2017/12
N2 - Purpose To investigate the tensile properties of several components used to secure extraocular muscle to sclera in strabismus surgery to determine potential failure points. Methods A digital force gauge measured the tensile strength of intact or damaged 6-0 Vicryl suture (Ethicon, Somerville, NJ), as well as threads tied in a 2-1-1 or 2-1-1-1 surgeon's knot configuration. Human sclera was used to test the resistance to drag of knotted and unknotted 6-0 Vicryl suture thread through partial thickness sclera. Mean values were compared using a t test. Results The mean tensile strength of 6-0 Vicryl suture was 623.5 g, but it was markedly reduced by damage from the needle (P < 0.0001) or ophthalmic needle holder (P < 0.0001). The 2-1-1 knots broke at a mean force of 307.6 g, compared with 292.8 g for 2-1-1-1 knots (P = 0.84). Drag through a 2 mm scleral tunnel was 4.6 g, compared to 13.6 g for a 4 mm tunnel (P = 0.011). The force required to pull a knotted suture through a 4 mm scleral tunnel was 254 g for a 2-1-1 knot and 367 g for a 2-1-1-1 knot (P < 0.015). Conclusions Although 6-0 Vicryl possesses adequate tensile strength for muscle fixation, thread damage from a needle or needle holder may cause serious losses in tensile strength. Knot-breaking strength is not significantly increased by adding a fourth throw. Frictional forces of the scleral tunnel are not sufficient to provide muscle stabilization, but the presence of a knot can provide substantial resistance to suture slip into the scleral tunnel.
AB - Purpose To investigate the tensile properties of several components used to secure extraocular muscle to sclera in strabismus surgery to determine potential failure points. Methods A digital force gauge measured the tensile strength of intact or damaged 6-0 Vicryl suture (Ethicon, Somerville, NJ), as well as threads tied in a 2-1-1 or 2-1-1-1 surgeon's knot configuration. Human sclera was used to test the resistance to drag of knotted and unknotted 6-0 Vicryl suture thread through partial thickness sclera. Mean values were compared using a t test. Results The mean tensile strength of 6-0 Vicryl suture was 623.5 g, but it was markedly reduced by damage from the needle (P < 0.0001) or ophthalmic needle holder (P < 0.0001). The 2-1-1 knots broke at a mean force of 307.6 g, compared with 292.8 g for 2-1-1-1 knots (P = 0.84). Drag through a 2 mm scleral tunnel was 4.6 g, compared to 13.6 g for a 4 mm tunnel (P = 0.011). The force required to pull a knotted suture through a 4 mm scleral tunnel was 254 g for a 2-1-1 knot and 367 g for a 2-1-1-1 knot (P < 0.015). Conclusions Although 6-0 Vicryl possesses adequate tensile strength for muscle fixation, thread damage from a needle or needle holder may cause serious losses in tensile strength. Knot-breaking strength is not significantly increased by adding a fourth throw. Frictional forces of the scleral tunnel are not sufficient to provide muscle stabilization, but the presence of a knot can provide substantial resistance to suture slip into the scleral tunnel.
UR - http://www.scopus.com/inward/record.url?scp=85031896727&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85031896727&partnerID=8YFLogxK
U2 - 10.1016/j.jaapos.2017.03.015
DO - 10.1016/j.jaapos.2017.03.015
M3 - Article
C2 - 28989101
AN - SCOPUS:85031896727
SN - 1091-8531
VL - 21
SP - 457-459.e1
JO - Journal of AAPOS
JF - Journal of AAPOS
IS - 6
ER -