TY - JOUR
T1 - Subcuticular closure versus dermabond
T2 - A prospective randomized trial
AU - Switzer, Erin F.
AU - Dinsmore, Robert C.
AU - North, James H.
PY - 2003/12/1
Y1 - 2003/12/1
N2 - 2-Octylcyanoacrylate tissue adhesive (Dermabond™, Ethicon, Inc, Somerville, NJ) is being used successfully for closure of minor lacerations. To date, however, there have been no studies evaluating its use in the operating room for surgical incisions. We conducted a prospective randomized trial to compare the closure of inguinal herniorrhaphy incisions using 2-octylcyanoacrylate tissue adhesive (Dermabond) with closures using 4-0 Monocryl (Ethicon, Inc) in a running subcuticular closure. A total of 46 incisions were randomized at the time of closure. Of these incisions 24 were randomized to Dermabond closure (TA) and 22 were randomized to subcuticular closure (SC). Performance measures included: time for closure, wound complications, and cosmesis. Cosmesis was evaluated by blinded evaluation of photographs of the incisions taken 4 weeks after surgery. Closure times for the TA group were faster than in the SC group (mean of 155 vs 286 seconds; P < 0.001). Wound complications were higher in the TA group (P = 0.045). Cosmesis was also felt to be better in the SC group with a score of 4.2 versus 3.88, but this did not reach statistical significance. Although the use of Dermabond did result in faster wound cultures it also resulted in an increase in wound complications. The difference in mean cosmetic score for each group was not statistically significant but trended toward better scores in the SC group. Based on these findings we do not feel Dermabond is an acceptable alternative to subcuticular suture closure in inguinal herniorrhaphy incisions.
AB - 2-Octylcyanoacrylate tissue adhesive (Dermabond™, Ethicon, Inc, Somerville, NJ) is being used successfully for closure of minor lacerations. To date, however, there have been no studies evaluating its use in the operating room for surgical incisions. We conducted a prospective randomized trial to compare the closure of inguinal herniorrhaphy incisions using 2-octylcyanoacrylate tissue adhesive (Dermabond) with closures using 4-0 Monocryl (Ethicon, Inc) in a running subcuticular closure. A total of 46 incisions were randomized at the time of closure. Of these incisions 24 were randomized to Dermabond closure (TA) and 22 were randomized to subcuticular closure (SC). Performance measures included: time for closure, wound complications, and cosmesis. Cosmesis was evaluated by blinded evaluation of photographs of the incisions taken 4 weeks after surgery. Closure times for the TA group were faster than in the SC group (mean of 155 vs 286 seconds; P < 0.001). Wound complications were higher in the TA group (P = 0.045). Cosmesis was also felt to be better in the SC group with a score of 4.2 versus 3.88, but this did not reach statistical significance. Although the use of Dermabond did result in faster wound cultures it also resulted in an increase in wound complications. The difference in mean cosmetic score for each group was not statistically significant but trended toward better scores in the SC group. Based on these findings we do not feel Dermabond is an acceptable alternative to subcuticular suture closure in inguinal herniorrhaphy incisions.
UR - http://www.scopus.com/inward/record.url?scp=0038348617&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0038348617&partnerID=8YFLogxK
M3 - Article
C2 - 12769218
AN - SCOPUS:0038348617
SN - 0003-1348
VL - 69
SP - 434
EP - 436
JO - American Surgeon
JF - American Surgeon
IS - 5
ER -