TY - JOUR
T1 - Transesophageal Echocardiography-Guided Epicardial Left Ventricular Lead Placement by Video-Assisted Thoracoscopic Surgery in Nonresponders to Biventricular Pacing and Previous Chest Surgery
AU - Schroeder, Carsten
AU - Chung, Jane M.
AU - Mackall, Judith A.
AU - Cakulev, Ivan T.
AU - Patel, Aaron
AU - Patel, Sunny J.
AU - Hoit, Brian D.
AU - Sahadevan, Jayakumar
N1 - Publisher Copyright:
© 2018 by the International Society for Minimally Invasive Cardiothoracic Surgery.
PY - 2018/5/1
Y1 - 2018/5/1
N2 - Objective The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Methods Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. Results The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. Conclusions In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.
AB - Objective The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Methods Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. Results The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. Conclusions In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.
KW - Biventricular pacing
KW - Left ventricular lead placement
KW - Minimally invasive surgery
KW - Reoperation
KW - Resynchronization therapy
UR - http://www.scopus.com/inward/record.url?scp=85049398466&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85049398466&partnerID=8YFLogxK
U2 - 10.1097/IMI.0000000000000508
DO - 10.1097/IMI.0000000000000508
M3 - Article
C2 - 29912139
AN - SCOPUS:85049398466
SN - 1556-9845
VL - 13
SP - 211
EP - 217
JO - Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
JF - Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
IS - 3
ER -