A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation, and radiochromic film

  • Ahmad Amoush(corresponding author)
    ,
  • Marcus Luckstead
    ,
  • Michael Lamba
    ,
  • Howard Elson
    ,
  • William Kassing
*Corresponding author for this work
  • University of Cincinnati
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

This study aimed to investigate the high-dose rate Iridium-192 brachytherapy, including near source dosimetry, of a catheter-based applicator from 0.5. mm to 1. cm along the transverse axis. Radiochromic film and Monte Carlo (MC) simulation were used to generate absolute dose for the catheter-based applicator. Results from radiochromic film and MC simulation were compared directly to the treatment planning system (TPS) based on the American Association of Physicists in Medicine Updated Task Group 43 (TG-43U1) dose calculation formalism. The difference between dose measured using radiochromic film along the transverse plane at 0.5. mm from the surface and the predicted dose by the TPS was 24%±13%. The dose difference between the MC simulation along the transverse plane at 0.5. mm from the surface and the predicted dose by the TPS was 22.1%±3%. For distances from 1.5. mm to 1. cm from the surface, radiochromic film and MC simulation agreed with TPS within an uncertainty of 3%. The TPS under-predicts the dose at the surface of the applicator, i.e., 0.5. mm from the catheter surface, as compared to the measured and MC simulation predicted dose. MC simulation results demonstrated that 15% of this error is due to neglecting the beta particles and discrete electrons emanating from the sources and not considered by the TPS, and 7% of the difference was due to the photon alone, potentially due to the differences in MC dose modeling, photon spectrum, scoring techniques, and effect of the presence of the catheter and the air gap. Beyond 1. mm from the surface, the TPS dose algorithm agrees with the experimental and MC data within 3%.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 160-164 (5 pages)

Journal (Volume, Issue Number)

Medical Dosimetry (Volume 38, Issue 2)

Publication milestones

  • Published - 2013

Publication status

Published - 2013

ISSN

0958-3947

Publication IDs

  • Scopus: 84876980367
  • PubMed: 23246195

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1
SciVal
Author count
5
SciVal
Paper percentile
24

PlumX, opens in new tab

Citation count
5
Captures
12