Abstract

Background Reflectance confocal microscopy (RCM) increases specificity of identification of basal cell carcinoma (BCC). A smaller-diameter handheld RCM (HH-RCM) allows better access to limited anatomic locations. Objective To compare accuracy of HH-RCM in identification of BCC to that of traditional wide-probe RCM (TWP-RCM). Methods Patients presenting at least one lesion clinically and dermoscopically suspicious for BCC, were recruited from two dermatology skin cancer clinics. Prior to excision, we attempted to image all lesions with HH-RCM and TWP-RCM using a standardized protocol. RCM images were retrospectively evaluated, jointly by two blinded readers. For purposes of comparative RCM, sensitivity and specificity analysis, we used a threshold of ≥3 RCM criteria to identify BCC, whereby at least one criterion had to be presence of 'dark silhouettes' or 'bright tumor islands'. Results Among 54 lesions imaged with both RCM devices, 45 were biopsy-proven BCCs. Comparison between TWP-RCM vs. HH-RCM was as follows: sensitivity (100% vs. 93%), specificity (78% for both probes), positive predictive value (96% vs. 95%), and negative predictive value (100% vs. 70%) respectively. Notably, both TWP-RCM and HH-RCM demonstrated the presence of 'dark silhouettes' or 'bright tumor islands' in all 45 BCCs. Conclusion Both RCM probes demonstrate high PPV. TWP-RCM shows higher NPV, since its broader field-of-view probably allows more exhaustive search for BCC criteria. The RCM criteria threshold for BCC identification should be further tested.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 1164-1169 (6 pages)

Journal (Volume, Issue Number)

Journal of the European Academy of Dermatology and Venereology (Volume 29, Issue 6)

Publication milestones

  • Published - 06/01/2015

Publication status

Published - 06/01/2015

ISSN

0926-9959

Publication IDs

  • Scopus: 84929650657
  • PubMed: 25338750

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.14
Fractional count
6
Fractional count
0.86
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
30
Citation count
45