Artificial Intelligence Model for Time Series Classification: Prediction of Delayed Balloon Expulsion Test Using High-Resolution Anorectal Manometry Data and Time-Series Integrated Pressurized Volume
- Myeongsook Seo,
- Kiwon Yoon,
- Kee Wook Jung(corresponding author),
- Seung Jae Myung,
- ,
- Segyeong Joo(corresponding author)
- University of Ulsan,
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOpen access
Abstract
<p>Background: We previously demonstrated the novel concept of using the integrated pressurized volume (IPV) with high-resolution anorectal manometry (HRAM) and found that it was predictive of delayed balloon expulsion (BE) test results. However, previous IPV methods did not account for chronological changes in anorectal force. To fully utilize the temporal dynamics of HRAM data and enhance BE test prediction, we introduced time-series IPVs (TS-IPVs) and developed an artificial intelligence (AI)-based diagnostic model. Methods: A total of 300 patients with constipation (130 male and 170 female patients) were enrolled and underwent HRAM and BE tests from September 2020 to May 2021. The TS-IPVs were calculated within a particular time interval during the push maneuver. Convolutional neural networks (CNNs) and a long short-term memory (LSTM) network were applied to predict BE test results. Key Results: Delayed BE was observed in 69 (53.1%) male and 49 (28.8%) female patients. According to the receiver operating characteristic curve analysis, the TS-IPV ratio between the upper 1 cm and lower 3 cm of the anal canal (TS-IPV<sub>13</sub> ratio) was the best parameter for predicting BE test results in all patients. Using the TS-IPV<sub>13</sub> ratio, the proposed model achieved area under the curve (AUC) values of 0.988 and 0.996 for female and male patients, respectively. Conclusions and Inferences: Our AI model accurately classified delayed BE test results using raw HRAM data and TS-IPVs of male and female patients with an AUC of 0.99. Furthermore, the model used time-variant HRAM pressure data and TS-IPVs throughout the push maneuver without any data loss; therefore, TS-IPV could be used as a more reliable marker than conventional parameters for classifying delayed BE test results.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
English (US)Article number
e70044Journal (Volume, Issue Number)
Neurogastroenterology and Motility (Volume 37, Issue 9)Publication milestones
- Published - 09/2025
Publication status
Published - 09/2025
ISSN
1350-1925Publication IDs
- Scopus: 105002144088
- PubMed: 40179281
Publication metrics
Metrics
Fractional count
1
Fractional count
0.17
Fractional count
5
Fractional count
0.83
Fractional count
1
Fractional count
1
PlumX, opens in new tab
Mentions
1
Citation count
4
Captures
3
Funding Details
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (NRF‐2021R1G1A1008311) and the Korean Society of Neurogastroenterology and Motility (KSNM‐20‐02). Funding:
Funding: This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (NRF-2021R1G1A1008311) and the Korean Society of Neurogastroenterology and Motility (KSNM-20-02).
FundersFunding numbers
NRF
-NRF-2021R1G1A1008311
-MSIT
NRF‐2021R1G1A1008311
KSNM
KSNM‐20‐02
