Skip to search boxSkip to navigationSkip to main content

Assessment of pulmonary and cardiac function after high dose chemotherapy with BEAM and peripheral blood progenitor cell transplantation

  • Emile Salloum
    ,
  • ,
  • Rajani Nadkarni
    ,
  • Stuart Seropian
    ,
  • Grace L. Hu
    ,
  • Elizabeth D'Andrea
*Corresponding author for this work
  • Yale University
    ,
  • Yale Cancer Center
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Open access

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

<p>BACKGROUND. Limited information is available regarding the cardiac and pulmonary effects of high dose chemotherapy (HDCT) and autologous peripheral blood progenitor cell (PBPC) transplantation. METHODS. The authors evaluated cardiac and pulmonary function after BEAM (BCNU 300 mg/m<sup>2</sup>, etoposide 400 mg/m<sup>2</sup>/day x 3 days, cytosine arabinoside 200 mg/m<sup>2</sup>/day x 4 days, and melphalan 140 mg/m<sup>2</sup>), HDCT, and PBPC transplantation in 26 patients with non-Hodgkin's lymphoma or Hodgkin's disease. Therapy prior to BEAM included doxorubicin (25 patients), bleomycin (6 patients), and mediastinal irradiation (4 patients). All patients had pulmonary function tests (PFTs) and equilibrium radionuclide angiography before and at a median of 57 weeks after transplantation. RESULTS. Prior to high dose therapy, 8 patients had abnormal PFTs, including 6 with a diffusing capacity of the lung for carbon monoxide (DLCO) <70% of predicted value. At the time of reevaluation after HDCT, all patients included in the study were in complete remission, and none had received additional therapy after transplantation. At a median of 77 weeks after transplantation, none of the patients had cardiac or pulmonary symptoms. Moreover, there were no significant changes in total lung capacity, forced vital capacity, forced expiratory volume in 1 second/forced vital capacity, DLCO, or left ventricular ejection fraction values when compared with baseline studies. CONCLUSIONS. The authors concluded that HDCT with BEAM and PBPC transplantation did not result in significant cardiac or pulmonary toxicity, even in patients with borderline pretransplantation PFT values. Further studies of patients undergoing HDCT and PBPC transplantation are needed.</p>

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 1506-1512 (7 pages)

Journal (Volume, Issue Number)

Cancer (Volume 82, Issue 8)

Publication milestones

  • Published - 04/15/1998

Publication status

Published - 04/15/1998

ISSN

0008-543X

Publication IDs

  • Scopus: 0032523083
  • PubMed: 9554528

Publication metrics

Metrics

SciVal
citations
9
SciVal
FWCI
0.52
SciVal
Author count
8
SciVal
Paper percentile
56
Fractional count
1
Fractional count
0.13
Fractional count
7
Fractional count
0.88
Fractional count
1
Fractional count
1
Scopus
citations

PlumX, opens in new tab

Citation count
10
Captures
20