Automatic tracking of rolling leukocytes in vivo
- Scott T. Acton(corresponding author),
- Klaus Wethmar,
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewAbstract
<p>The analysis of instantaneous and average rolling leukocyte velocity is crucial to the study of inflammatory disease. In order to record features associated with leukocyte rolling, the leukocyte position must be tracked, typically by manual observation. Automated tracking of leukocytes is possible for in vitro studies, but not for recordings resulting from intravital experiments. Therefore, we have designed and implemented an image processing system for automated tracking of rolling leukocytes in vivo. The novel image processing techniques used in the tracking system successfully address the four major problems associated with tracking cells in vivo: background movement, severe image noise and clutter, cell deformation and contrast change, and occlusion of the target cell by other structures. We have tested the system in two experimental protocols in which leukocyte rolling is observed in venules of the mouse cremaster muscle with and without TNF-α treatment. The automated tracking system was validated by comparing automatically generated displacement and velocity data with data from the same recordings collected manually. The root mean squared error between the computed displacements and the manually measured displacements was less than 12% of the average displacement in TNF-α-treated venules. The average velocity error was also less than 12%. For untreated venules, the computed and measured displacements and velocities had an RMSE of less than 8%. The automated tracking system allows one, for the first time, to reliably track rolling leukocytes in vivo, thus eliminating possible investigator bias and increasing throughput.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 139-148 (10 pages)Journal (Volume, Issue Number)
Microvascular Research (Volume 63, Issue 1)Publication milestones
- Published - 2002
Publication status
Published - 2002
ISSN
0026-2862Publication IDs
- Scopus: 0036354738
- PubMed: 11749081
Publication metrics
Metrics
Fractional count
1
Fractional count
0.33
Fractional count
2
Fractional count
0.67
Fractional count
1
Fractional count
1
PlumX, opens in new tab
Captures
30
Citation count
48
Funding Details
This work was in part supported by NIH R01 HL 64381 to KL. STA is supported in part by the Army Research Office under DAAD19-01-1-0594.
FundersFunding numbers
NIH
R01 HL 64381
ARO
DAAD19-01-1-0594
