Skip to search boxSkip to navigationSkip to main content

Binding and detachment dynamics of microbubbles targeted to P-selectin under controlled shear flow

  • Amol M. Takalkar
    ,
  • Alexander L. Klibanov
    ,
  • Joshua J. Rychak
    ,
  • Jonathan R. Lindner
    ,
  • Klaus Ley(corresponding author)
*Corresponding author for this work
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Abstract

<p>This study was performed to assess the binding kinetics of a targeted microbubble contrast agent exposed to shear stress. An ultrasound contrast targeted to P-selectin was designed by conjugating monoclonal antibodies against murine P-selectin (RB40.34) to the lipid monolayer shell of the microbubble using poly(ethylene glycol)-biotin-streptavidin. The attachment and detachment of targeted microbubbles to P-selectin immobilized on a culture dish were assessed in a parallel-plate flow chamber. Targeted microbubbles (5×10<sup>6</sup> particles/ml) drawn through the flow chamber coated with P-selectin (109 sites/μm<sup>2</sup>) at a shear stress of 0.3 dyn/cm <sup>2</sup> accumulated at a rate of 565 mm<sup>-2</sup> min<sup>-1</sup>. Attachment rates increased at higher plate surface densities of P-selectin, and microbubble detachment was reduced. Accumulation rate first increased with shear stress, reached a maximum at ∼0.6 dyn/cm<sup>2</sup> and then decreased. Control experiments on a plate that lacked P-selectin, or was blocked with mAb RB40.34, resulted in minimal bubble attachment. Microbubble detachment was tested by ramping up shear stress at 30-s intervals. Half-maximal detachment was reached at 34 dyn/cm<sup>2</sup>. Overall, accumulation and retention of targeted ultrasound contrast agents is possible under physiologic flow conditions and is strongly influenced by shear stress and surface density of the target receptor.</p>

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 473-482 (10 pages)

Journal (Volume, Issue Number)

Journal of Controlled Release (Volume 96, Issue 3)

Publication milestones

  • Published - 05/18/2004

Publication status

Published - 05/18/2004

ISSN

0168-3659

Publication IDs

  • Scopus: 2142758635
  • PubMed: 15120903

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
125
Citation count
212
Mentions
3

Funding Details

This work was supported by NIH BRP HL 64381 and a research grant from the Whitaker Foundation to K. Ley. J.J. Rychak is supported via NIH training grant HL07284. Generous donation of laboratory equipment to A.L. Klibanov's laboratory at UVA Cardiovascular Imaging Center by Mallinckrodt (St. Louis, MO) is appreciated. A.L. Klibanov is supported in part via DOE 43-14702, NIH DK63508 and HL64381. J.R. Lindner is supported in part via NIH DK63508, HL64381 and Grant-in-Aid GF10013 from the Atlantic Coast Affiliate of American Heart Association, Baltimore MD. A grant from the EIF Foundation to UVA Cardiovascular Division is gratefully acknowledged.