Skip to search boxSkip to navigationSkip to main content

Clinical experience with a chlorhexidine-coated PICC: A prospective, multicenter, observational study

  • Michael A. Winkler
    ,
  • Timothy R. Spencer(corresponding author)
    ,
  • Nasir Siddiqi
    ,
  • Jessica E. Wallace
    ,
  • John Z. Gallien
    ,
  • Hossam Elbalasi
*Corresponding author for this work
  • ,
  • LLC
    ,
  • Baylor College of Medicine
    ,
  • University of California at Los Angeles
    ,
  • Wayne State University
    ,
  • University of Kentucky
Scholary Output:
Contribution to journal
Article
Peer-review

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

Introduction: This study evaluated a chlorhexidine-coated peripherally inserted central catheter (PICC) and the incidence of associated complications within both inpatient and outpatient populations. Methods: This IRB-approved, multicenter, prospective observational study was performed at three large teaching hospitals in the US. All adults who required a PICC for ⩾14 days were considered. Patients were monitored throughout entire catheter dwell. Duplex venous ultrasounds were performed before insertion, after 10 to 14 days of dwell time, and upon removal. Data was collected from the hospital, outpatient clinic, and patient PICC diary records. Results: A total of 103 patients, 56% male, with mean BMI 29 ± 8.8, were enrolled. The majority (79%) of patients were from high-risk groups—cancer, infectious diseases, transplant, and trauma. Primary treatment indications were antibiotics (66.99%) and chemotherapy (25.24%). Double lumen PICCs (59.2%) were favored clinically, as was basilic vein placement (71.84%). Mean catheter dwell was 47.01 ± 25.82 days. Three (3, 2.9%) central line-associated bloodstream infections (CLABSI) were reported. Four patients (4.6%) reported symptomatic catheter-related thrombosis (CRT), confirmed with ultrasound. Three patients (3.4%) had ultrasound-confirmed fibroblastic sleeve (FS). Eight patients (9.2%) who entered the study with pre-existing superficial thrombosis, had complete resolution at the time of catheter removal. The incidence of CLABSI was 0.82/1000 days. The combined CRT and FS rate was 6.9%. Conclusion: Based upon the observational findings of this study, chlorhexidine-coated PICC technology may be considered for use in patient populations who are at moderate to high-risk for catheter-related complications in both inpatient and outpatient settings.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 225-231 (7 pages)

Journal (Volume, Issue Number)

Journal of Vascular Access (Volume 25, Issue 1)

Publication milestones

  • Accepted/In press - 2021
  • Published - 01/2024

Publication status

Published - 01/2024

ISSN

1129-7298

Publication IDs

  • Scopus: 85116776205

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.11
Fractional count
8
Fractional count
0.89
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
37
Citation count
6

Funding Details

The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This study was sponsored by Teleflex Inc., (Morrisville, NC, USA), manufacturer of the chlorhexidine-coated PICC used in this study. The primary investigator institutions involved received a research grant to perform this study.
FunderFunding numbers
Teleflex Inc.
-