Clinical performance of anterior resin-bonded fixed dental prostheses with different framework designs: A systematic review and meta-analysis
- Ya Ru Wei,
- Xiao Dong Wang,
- Qin Zhang,
- Xiang Xia Li,
- Markus B. Blatz,
- Yu Tao Jian(corresponding author)
- Sun Yat-Sen University,
Scholary Output:
Contribution to journal
Review article
Research
Peer-reviewAbstract
<p>Objectives To systematically review the failure rate and complications of different framework designs of resin-bonded fixed dental prostheses (RBFDPs) in the anterior region. Methods A systematic search for clinical studies on RBFDPs published prior to December 2014 in Medline/PubMed, EMBASE, and Cochrane Library databases was conducted and complemented by a manual search. Randomized controlled trials (RCTs) as well as prospective and retrospective cohort studies that compared at least two RBFDP framework designs with a minimum of 2 years follow up were included in this review. The quality of the included studies were assessed using the Newcastle-Ottawa scale for cohort studies and Cochrane Handbook for RCT. Prostheses-based data on reported failure rate/survival rate, debonding, and fractures were analyzed by meta-analysis. Results Of 1010 screened articles, one RCT and 4 cohort studies fit the inclusion criteria and were included in the meta-analysis. All included articles have a high risk of bias. Failure rates of single-retainer cantilever RBFDPs were lower than two-retainer fixed-fixed RBFDPs (OR 0.42, 95% CI 0.19-0.94, P = 0.04). Metal-ceramic RBFDPs showed no difference of failure rates between cantilever RBFDPs and two-retainer fixed-fixed RBFDPs (OR 0.93, 95% CI 0.33-2.63, P = 0.89). Debonding was not significantly different between cantilever RBFDPs and two-retainer fixed-fixed RBFDPs (OR 0.61, 95% CI 0.23-1.60, P = 0.32). Metal-ceramic RBFDPs showed no difference of debonding between cantilever RBFDPs and two-retainer fixed-fixed RBFDPs (OR 0.81, 95% CI 0.28-2.34, P = 0.70,). Conclusions Within the limitations of the present study, cantilever RBFDPs demonstrate lower clinical failure than two-retainer RBFDPs in the anterior region. The failure of metal-ceramic RBFDPs is independent of the framework design, while the failure of all-ceramic RBFDPs with different designs has not been clear yet. Clinical significance Based on the principle of minimally invasive treatment, less number of retainers is recommended for RBFDPs.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Review article
Research
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 1-7 (7 pages)Journal (Volume, Issue Number)
Journal of Dentistry (Volume 47)Publication milestones
- Accepted/In press - 04/05/2015
- Published - 04/01/2016
Publication status
Published - 04/01/2016
ISSN
0300-5712Publication IDs
- Scopus: 84975677604
- PubMed: 26875611
Publication metrics
Metrics
Fractional count
1
Fractional count
0.14
Fractional count
6
Fractional count
0.86
Fractional count
1
Fractional count
1
SciVal
FWCI
2.17
SciVal
Author count
7
SciVal
citations
27
SciVal
Paper percentile
90
SciVal
Top percentile
10
PlumX, opens in new tab
Mentions
1
Captures
168
Citation count
65