Skip to search boxSkip to navigationSkip to main content

Clinical validation and applications for CT-based atlas for contouring the lower cranial nerves for head and neck cancer radiation therapy

  • Waleed F. Mourad(corresponding author)
    ,
  • Brett M. Young
    ,
  • Rebekah Young
    ,
  • Dukagjin M. Blakaj
    ,
  • Nitin Orhi
    ,
  • Rania A. Shourbaji
*Corresponding author for this work
  • Albert Einstein College of Medicine
    ,
  • Continuum Health Partners, Inc.
    ,
  • Duke University
    ,
  • University of Mississippi
Scholary Output:
Contribution to journal
Article
Peer-review

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

Objectives Radiation induced cranial nerve palsy (RICNP) involving the lower cranial nerves (CNs) is a serious complication of head and neck radiotherapy (RT). Recommendations for delineating the lower CNs on RT planning studies do not exist. The aim of the current study is to develop a standardized methodology for contouring CNs IX-XII, which would help in establishing RT limiting doses for organs at risk (OAR). Methods Using anatomic texts, radiologic data, and guidance from experts in head and neck anatomy, we developed step-by-step instructions for delineating CNs IX-XII on computed tomography (CT) imaging. These structures were then contoured on five consecutive patients who underwent definitive RT for locally-advanced head and neck cancer (LAHNC). RT doses delivered to the lower CNs were calculated. Results We successfully developed a contouring atlas for CNs IX-XII. The median total dose to the planning target volume (PTV) was 70 Gy (range: 66-70 Gy). The median CN (IX-XI) and (XII) volumes were 10 c.c (range: 8-12 c.c) and 8 c.c (range: 7-10 c.c), respectively. The median V50, V60, V66, and V70 of the CN (IX-XI) and (XII) volumes were (85, 77, 71, 65) and (88, 80, 74, 64) respectively. The median maximal dose to the CN (IX-XI) and (XII) were 72 Gy (range: 66-77) and 71 Gy (range: 64-78), respectively. Conclusions We have generated simple instructions for delineating the lower CNs on RT planning imaging. Further analyses to explore the relationship between lower CN dosing and the risk of RICNP are recommended in order to establish limiting doses for these OARs.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 956-963 (8 pages)

Journal (Volume, Issue Number)

Oral Oncology (Volume 49, Issue 9)

Publication milestones

  • Published - 09/2013

Publication status

Published - 09/2013

ISSN

1368-8375

Publication IDs

  • Scopus: 84883132837
  • PubMed: 23623404

Publication metrics

Metrics

Scopus
citations
SciVal
citations
9
Fractional count
1
Fractional count
0.06
Fractional count
17
Fractional count
0.94
Fractional count
1
Fractional count
1
SciVal
FWCI
0.32
SciVal
Author count
18
SciVal
Paper percentile
64

PlumX, opens in new tab

Captures
46
Citation count
14