Clinically relevant issues related to preheating composites.

*Corresponding author for this work
  • Universidade de São Paulo
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

STATEMENT OF THE PROBLEM: Issues regarding the use of composite preheating need to be investigated so that the clinician will better understand the variables associated with this method. Purpose: To examine the multiple aspects of use of a commercial composite preheating device (Calset, AdDent Inc., Danbury, CT, USA). MATERIALS AND METHODS: Temperature values of three heating units and composite compules were obtained using a K-type thermocouple and were recorded digitally in real time. The following parameters were measured: maximum heater and composite temperature and its stability upon storage, composite temperature change when removed from the heater and injected, the effect of delivery system on ejected composite temperature, and the effect of repeated and extended preheating on composite monomer conversion (using infrared spectroscopy). Monomer conversion was measured after repeated composite cycling (from room temperature [RT] to 60 degrees C, 10x) or extended preheating (24 hours at 60 degrees C), and values were compared with composite maintained at RT (control group). Among test parameters, data (N=5 for each parameter) were analyzed using Student's t-test, analysis of variance, and the Tukey-Kramer post-hoc test where appropriate (alpha=0.05). RESULTS/CONCLUSIONS: Two of the three tested units achieved the stated preset temperatures. Composite attained temperature values close to the heating unit. Composite temperature drop upon removal from the heater was dramatic: within 2 minutes a 50% temperature drop was noted. Heating the compule while preloaded in the syringe provided higher delivery temperatures than heating the compule separately (p < 0.00). Optimum results were achieved when preheated composite was dispensed and used as quickly as possible. Neither repeated nor extended preheating of composite significantly affected monomer conversion. CLINICAL SIGNIFICANCE: Preheating composite has potential benefits, but should be used with knowledge of its limitations. Reheating of unused composite does not affect its degree of conversion, thus decreasing material waste. Heating of the composite preloaded in the delivery syringe enhances the temperature of extruded composite.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 340-350; discussion 351

Journal (Volume, Issue Number)

Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] (Volume 18, Issue 6)

Publication milestones

  • Published - 2006

Publication status

Published - 2006

ISSN

1496-4155

Publication IDs

  • Scopus: 34547672718
  • PubMed: 17083439
  • ORCID: /0000-0003-1947-3337/work/65875980

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.25
Fractional count
3
Fractional count
0.75
Fractional count
1
Fractional count
1
SciVal
citations
66
SciVal
FWCI
1.77
SciVal
Author count
4
SciVal
Paper percentile
91
SciVal
Top percentile
10

PlumX, opens in new tab

Captures
126
Mentions
1
Citation count
135