Skip to search boxSkip to navigationSkip to main content

Combined C-arm fluoroscopy and C-arm cone beam computed tomography for the evaluation of patients with possible intrathecal baclofen delivery system malfunctions

  • Andrew Schapiro
    ,
  • John Racadio
    ,
  • Douglas Kinnett
    ,
  • Todd Maugans(corresponding author)
*Corresponding author for this work
  • Health Alliance
    ,
  • Cincinnati Children's Hospital Medical Center
Scholary Output:
Contribution to journal
Review article
Peer-review

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

BACKGROUND: Evaluating intrathecal baclofen (ITB) delivery systems for potential malfunction can be challenging. The catheter systems are prone to myriad complications that are frequently difficult to ascertain by conventional imaging techniques. Newer imaging technologies and their combinations can be used to identify such problems, define surgical indications, and focus operative planning. C-arm fluoroscopy and C-arm cone beam CT performed in one imaging session represents one such combination that has great utility. OBJECTIVE: We present a case series of ITB catheter evaluations using combined C-arm fluoroscopy (CF) and C-arm cone beam CT (CCBCT). METHODS: We retrospectively analyzed 7 pediatric patients who underwent ITB catheter systems evaluations by the use of combined CF and CCBCT. Study variables included indications for evaluation, imaging results, interventions, correlation of surgical findings with imaging, and clinical outcome. RESULTS: Three patients had intact and patent catheter systems. Four patients demonstrated various problems of the catheter systems, including disconnection, microfracture, fracture with segment migration, and subdural migration. Dosage adjustments improved all patients with normal studies. Surgery was guided by the imaging, and all operative patients improved after targeted interventions. Intraoperative findings correlated perfectly with imaging. CONCLUSION: Combined CF and CCBCT proved highly effective in the evaluation of our patients with potential ITB system malfunctions. This technique is advocated for such evaluations because it accurately defines problems with connectivity, integrity, and position of catheter systems. When surgical intervention is required, this information aids in operative planning.

Publication Information

Output type

Scholary Output:
Contribution to journal
Review article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages ons27-ons33

Journal (Volume, Issue Number)

Neurosurgery (Volume 69, Issue SUPPL. 1)

Publication milestones

  • Published - 09/2011

Publication status

Published - 09/2011

ISSN

0148-396X

Publication IDs

  • Scopus: 80051793067
  • PubMed: 21415786

Publication metrics

Metrics

SciVal
citations
5
SciVal
FWCI
0.31
SciVal
Author count
4
SciVal
Paper percentile
52
Fractional count
1
Fractional count
0.25
Fractional count
3
Fractional count
0.75
Fractional count
1
Fractional count
1
Scopus
citations

PlumX, opens in new tab

Citation count
6
Social media
453
Captures
10