Skip to search boxSkip to navigationSkip to main content

Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems

  • Rhett B. Casper
    ,
  • Howard W. Roberts
    ,
  • Mark D. Roberts
    ,
  • Van T. Himel
    ,
  • Brian E. Bergeron(corresponding author)
*Corresponding author for this work
  • United States Air Force Academy
    ,
  • Louisiana State University School of Dentistry
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Introduction: Recent innovative manufacturing techniques have produced nickel-titanium (NiTi) rotary instruments with reports of superior properties compared with standard NiTi files. These include Profile Vortex made from M-Wire (PV), Twisted Files (TF), and 10 Series files made from CM Wire (CM). Sterilization is recommended before use and is repeated if files are reused and/or carried forward between cases. The purpose for this study was to compare the effects of multiple autoclaving cycles on the torsional load resistance of these 3 new rotary endodontic files. Methods: PV, TF, and CM files (n = 100; size 25/.04) were divided into 5 groups (n = 20). Files were steam autoclaved for 1, 2, 3, and 7 sterilization cycles. A control group was not subjected to autoclaving. Files were tested in a torsiometer in general accordance with ISO 3630-1 standards. Torsional load and degrees of rotation to failure were recorded. Mean data were analyzed by using Kruskal-Wallace/Dunn post hoc tests (P <.05). Results: Autoclave cycles had no significant overall effect on file performance for any of the instrument systems tested. PV and CM displayed significantly greater resistance to torsional load than TF (P <.001) but were not different from each other (P >.05). Angular deflection values for TF and CM were significantly higher than for PV (P <.001), with TF demonstrating greater rotational distortion than CM (P <.05). Conclusions: Under the conditions of this study, repeated steam autoclaving did not affect torsional resistance for unused files of the systems evaluated. In addition, CM Wire files might have a combined advantage of greater torsional strength and high deformation before failure.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 1572-1575 (4 pages)

Journal (Volume, Issue Number)

Journal of endodontics (Volume 37, Issue 11)

Publication milestones

  • Published - 11/2011

Publication status

Published - 11/2011

ISSN

0099-2399

Publication IDs

  • Scopus: 80054058231
  • PubMed: 22000466

Publication metrics

Metrics

SciVal
FWCI
1.04
SciVal
Author count
5
SciVal
citations
23
SciVal
Paper percentile
80
Scopus
citations
Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
136
Citation count
37