Comparison of the predictive accuracy of DNA array-based multigene classifiers across cDNA arrays and affymetrix GeneChips
- James Stec,
- Jing Wang,
- ,
- Mark Ayers,
- Sebastian Hoersch,
- David L. Gold
- Millennium Pharmaceuticals,
- Praecis Pharmaceuticals Incorporated,
- University of Texas Health Science Center at Houston
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOpen access
Sustainable Development Goals
- SDG 3 Good Health and Well
Abstract
<p>We examined how well differentially expressed genes and multigene outcome classifiers retain their class-discriminating values when tested on data generated by different transcriptional profiling platforms. RNA from 33 stage I-III breast cancers was hybridized to both Affymetrix GeneChip and Millennium Pharmaceuticals cDNA arrays. Only 30% of all corresponding gene expression measurements on the two platforms had Pearson correlation coefficient r ≥ 0.7 when UniGene was used to match probes. There was substantial variation in correlation between different Affymetrix probe sets matched to the same cDNA probe. When cDNA and Affymetrix probes were matched by basic local alignment tool (BLAST) sequence identity, the correlation increased substantially. We identified 182 genes in the Affymetrix and 45 in the cDNA data (including 17 common genes) that accurately separated 91% of cases in supervised hierarchical clustering in each data set. Cross-platform testing of these informative genes resulted in lower clustering accuracy of 45 and 79%, respectively. Several sets of accurate five-gene classifiers were developed on each platform using linear discriminant analysis. The best 100 classifiers showed average misclassification error rate of 2% on the original data that rose to 19.5% when tested on data from the other platform. Random five-gene classifiers showed misclassification error rate of 33%. We conclude that multigene predictors optimized for one platform lose accuracy when applied to data from another platform due to missing genes and sequence differences in probes that result in differing measurements for the same gene.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 357-367 (11 pages)Journal (Volume, Issue Number)
Journal of Molecular Diagnostics (Volume 7, Issue 3)Publication milestones
- Published - 08/2005
Publication status
Published - 08/2005
ISSN
1525-1578Publication IDs
- Scopus: 23844519571
- PubMed: 16049308
Publication metrics
Metrics
Fractional count
1
Fractional count
0.08
Fractional count
12
Fractional count
0.92
Fractional count
1
Fractional count
1
PlumX, opens in new tab
Captures
58
Citation count
49
Funding Details
FunderFunding number
NCI
R01CA106290
