Skip to search boxSkip to navigationSkip to main content

Continuous noninvasive hemoglobin monitor from pulse Ox: Ready for prime time?

  • Bellal Joseph(corresponding author)
    ,
  • Pantelis Hadjizacharia
    ,
  • Hassan Aziz
    ,
  • Kara Snyder
    ,
  • Julie Wynne
    ,
  • Narong Kulvatunyou
*Corresponding author for this work
  • University of Arizona
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Background: Advances in technology have allowed for continuous noninvasive hemoglobin monitoring (SpHb), which may enable earlier detection of hemorrhage and more efficient surgical and/or blood transfusion management. The use of SpHb has not been described in the trauma population. The purpose of the present study was to evaluate the accuracy of a SpHb measurement device in severely injured trauma patients. Methods: We performed a prospective cohort analysis of severely injured trauma patients admitted to the intensive care unit (ICU) at our level I trauma center over a 6 month period. Serial IHb (invasive hemoglobin) levels and SpHb for the first 72 h were measured. Each SpHb measurement was matched with a corresponding IHb measurement. We defined normal Hgb as >8 mg/dL and low Hgb as <8 mg/dL. Data were then grouped based on Hgb level. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and Spearman correlation coefficient plot were calculated. Results: A total of 23 trauma patients with 89 data pairs were reviewed. Eighty-six percent of the patients were male with a mean age of 32 years and a mean injury severity score (ISS) of 21.1 ± 14. Invasive hemoglobin had a range of 7.2-16.9 and SpHb had a range of 3.3-15.2. The average mean and difference between IHb and SpHb were 10.7 and 1, respectively. Continuous noninvasive hemoglobin measurement did not record data points 13.5 % of the time. The Spearman correlation plot revealed a correlation of R = 0.670 (p < 0.001). After dichotomization with Hgb > 8, SpHb was found to have a sensitivity of 91 %, PPV 96 %, specificity 40 %, NPV 20 %, and an accuracy of 88 %. Conclusions: The continuous noninvasive hemoglobin monitor does not appear to represent serum hemoglobin levels accurately in severely injured trauma patients. However, we were able to identify utility for this noninvasive tool when Hgb was dichotomized into normal or low levels.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 525-529 (5 pages)

Journal (Volume, Issue Number)

World Journal of Surgery (Volume 37, Issue 3)

Publication milestones

  • Published - 03/2013

Publication status

Published - 03/2013

ISSN

0364-2313

Publication IDs

  • Scopus: 84874118235
  • PubMed: 23196342

Publication metrics

Metrics

SciVal
citations
24
SciVal
FWCI
3.23
SciVal
Author count
11
SciVal
Paper percentile
83
Scopus
citations
Fractional count
1
Fractional count
0.09
Fractional count
10
Fractional count
0.91
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
24
Citation count
28