Skip to search boxSkip to navigationSkip to main content

Craniocervical fixation with occipital condyle screws: Biomechanical analysis of a novel technique

  • Juan S. Uribe
    ,
  • Edwin Ramos
    ,
  • A. Samy Youssef
    ,
  • Nick Levine
    ,
  • Alexander W.L. Turner
    ,
  • Wesley M. Johnson
  • University of South Florida
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Abstract

<p>Study Design: A human cadaveric biomechanical study comparing craniocervical fixation techniques. Objective: To quantitatively compare the biomechanical stability of a new technique for occipitocervical fixation using the occipital condyles with an established method for craniocervical spine fusion. Summary of Background Data: Stabilization of the occipitocervical junction remains a challenge. The occiput does not easily accommodate instrumentation because of access and spatial constraints. In fact, the area available for the implant fixation is limited and can be restricted further when a suboccipital craniectomy has been performed, posing a challenge to current fixation techniques. Occipital screws are also associated with the potential for intracranial complications. Methods: Six fresh frozen cadaveric specimens occiput-C4 were tested intact, after destabilization and after fixation as follows: (1) occipital plate with C1 lateral mass screws and C2 pars screws and (2) occipital condyle screws with C1 lateral mass screws and C2 pars screws. Specimens were loaded in a custom spine testing apparatus and subjected to the following tests, all performed under 50-N unconstrained axial preload: flexion, extension, lateral bending, and axial rotation at 1.5 Nm. The constructs were statistically compared with a one-way analysis of variance and compared with the intact condition. Results: Motions were reduced by ∼80% compared with the intact condition for both configurations under all motions. There were no statistically significant differences in the range of motion (ROM) between the 2 instrumentation conditions. The mean values indicated decreased ROM with the novel occipital condyle screw construct in comparison with the standard occipital plate and rod system. Conclusion: Craniocervical stabilization using occipital condyle screws as the sole cephalad fixation point is biomechanically equivalent with regard to the modes tested (ROM and stiffness) to the standard occipital plate construct.</p>

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 931-938 (8 pages)

Journal (Volume, Issue Number)

Spine (Volume 35, Issue 9)

Publication milestones

  • Published - 04/2010

Publication status

Published - 04/2010

ISSN

0362-2436

Publication IDs

  • Scopus: 77951768553
  • PubMed: 20375778

Publication metrics

Metrics

Scopus
citations
SciVal
citations
39
SciVal
FWCI
0.62
SciVal
Author count
7
SciVal
Paper percentile
87
Fractional count
1
Fractional count
0.14
Fractional count
6
Fractional count
0.86
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
36
Citation count
63