Skip to search boxSkip to navigationSkip to main content

Detection of Soft Tissue Foreign Bodies in the Presence of Soft Tissue Gas

  • ,
  • Larry Brannam
    ,
  • Douglas Johnson
    ,
  • Michael Blaivas(corresponding author)
    ,
  • Sandeep Duggal
*Corresponding author for this work
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Objective. To determine the effect of soft tissue gas on the accuracy of foreign body detection by real-time sonography. Methods. This was a prospective randomized study using glass, metal, and bone inserted into turkey breasts to simulate human soft tissue foreign bodies. Air was subsequently injected around a random selection of the foreign bodies to simulate soft tissue gas that can accompany a blast or high-force injury. Using a linear transducer, physicians credentialed in the use of sonography were each asked to scan the breasts, identify the location of any foreign body, and describe whether the object located was bone, metal, or glass. They were also asked to describe the characteristics of the foreign body, including surface echogenicity, visibility, and artifacts, if any. Results. The sensitivity for localization of each foreign body by each sonographer was 100% (48 of 48) and was unaffected by the presence of soft tissue gas. The accuracy of classifying the foreign body was poor except with bone. Glass and metal were often confused with each other. With the addition of soft tissue gas over the foreign bodies, the sensitivity of classifying the foreign body was decreased further from a combined 58% to 28%. The presence of soft tissue gas decreased the amount of reflection of the foreign body and obscured the subtle differences in the brightness of each foreign body, leading to a decrease in the accuracy of identification but not localization of the foreign body Condusions. In an experimental model, soft tissue gas does not affect the localization of soft tissue foreign bodies. However, correct identification of the type of foreign body is limited by soft tissue gas because of loss of the typical sonographic characteristics.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 677-681 (5 pages)

Journal (Volume, Issue Number)

Journal of Ultrasound in Medicine (Volume 23, Issue 5)

Publication milestones

  • Published - 05/2004

Publication status

Published - 05/2004

ISSN

0278-4297

Publication IDs

  • Scopus: 2342566490
  • PubMed: 15154535

Publication metrics

Metrics

SciVal
FWCI
0.31
SciVal
Author count
5
SciVal
citations
11
SciVal
Paper percentile
60
Scopus
citations
Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Citation count
18
Captures
23