Skip to search boxSkip to navigationSkip to main content

Diagnostic potential of serum proteomic patterns in prostate cancer

  • Lionel L. Bañez
    ,
  • Premkala Prasanna
    ,
  • Leon Sun
    ,
  • Amina Ali
    ,
  • Zhiqiang Zou
    ,
*Corresponding author for this work
  • Uniformed Services University of the Health Sciences
    ,
  • Eastern Virginia Medical School
    ,
  • Walter Reed Army Institute of Research
Scholary Output:
Contribution to journal
Article
Peer-review

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

Purpose: The serum prostate specific antigen test has been widely used in the last decade as an effective screening tool for prostate cancer (CaP). However, the high false-positive rate of the serum prostate specific antigen test necessitates the development of more accurate diagnostic and prognostic biomarkers for CaP. Promising diagnostic potential of serum protein patterns detected by surface enhanced laser desorption/ionization time of flight mass spectrometry for CaP has recently been reported. Independent evaluation of this new technology is warranted to realize its translational utility. We determined whether serum protein profiling by surface enhanced laser desorption/ionization time of flight mass spectrometry and a decision tree algorithm classification system could accurately discriminate between patients with CaP and unaffected individuals. Materials and Methods: Proteomic spectra of crude serum were generated using the Ciphergen ProteinChip System and pattern detection was performed using Biomarker Patterns Software (Ciphergen Biosystems, Inc., Fremont, California). A total of 106 patients with CaP and 56 controls were randomly allocated to a training set and a test set. The training set, which consisted of 44 patients with cancer and 30 controls, was used to build a decision tree algorithm. The test set, which consisted of 62 patients with cancer and 26 controls, was used in blinded fashion to validate the decision tree. Results: Accuracy of classification using the test set was 67% and 42% for the weak cation exchange array and the copper metal affinity capture array, respectively. Combined spectral data from the weak cation exchange and copper metal affinity capture arrays generated an algorithm that achieved 85% sensitivity and 85% specificity for the detection of CaP. Conclusions: These preliminary findings support recent observations that complex protein profiles have promising potential for the early detection of CaP and warrant future studies with streamlined technology. Furthermore, the combined effect of using 2 array types can greatly enhance the ability of protein profile patterns, suggesting the potential usefulness of alternative approaches to evaluate this new emerging technology.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 442-446 (5 pages)

Journal (Volume, Issue Number)

Journal of Urology (Volume 170, Issue 2 I)

Publication milestones

  • Published - 08/01/2003

Publication status

Published - 08/01/2003

ISSN

0022-5347

Publication IDs

  • Scopus: 1642557289
  • PubMed: 12853795

Publication metrics

Metrics

Scopus
citations
SciVal
citations
121
Fractional count
1
Fractional count
0.11
Fractional count
8
Fractional count
0.89
Fractional count
1
Fractional count
1
SciVal
FWCI
10.91
SciVal
Author count
9
SciVal
Paper percentile
95
SciVal
Top percentile
5

PlumX, opens in new tab

Citation count
127
Captures
41