Skip to search boxSkip to navigationSkip to main content

Dynamic SPET parameters of 123I-MIBG cardiac imaging

  • A. S. Arbab(corresponding author)
    ,
  • K. Koizumi
    ,
  • K. Toyama
    ,
  • T. Arai
    ,
  • T. Araki
*Corresponding author for this work
  • University of Yamanashi
    ,
  • Tokyo Medical University
Scholary Output:
Contribution to journal
Article
Peer-review

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

Early dynamic and late 123I-MIBG SPET studies were performed to investigate several parameters used to distinguish the characteristics of various cardiac disorders. Forty-six individuals (34 non-diabetic, 12 diabetic) with or without heart disease were included in the study. Early dynamic and late static SPET images were acquired using a triple-headed gamma camera. After selecting mid-sections from vertical (VLA) and horizontal (HLA) long-axis images, regions of interest were created over the apex, whole heart and anterior, inferior, septal and lateral walls of the heart. Various uptake ratios at 3,11 and 19 min and 4 h after injection (HU3, HU11, HU19, DUP) and clearances (Kse: between HU3 and HU11; Ke: between HU11 and HU19; Kd: between HU19 and DUP) were calculated. There were significant differences among various cardiac pathologies on the delayed images. Cardiomyopathy patients showed the lowest uptake on the delayed images. When all segments in normal patients and all involved segments in myocardial infarcted patients were compared, there was significantly lower uptake of MIBG in infarcted segments at all time points. Kd showed the lowest value compared with and Ke. In cardiomyopathy patients, Kse, and Kd were significantly different from each other. Both Kse and Ke were significantly higher in cardiomyopathy patients than in normal patients. In conclusion, the results of this study are in line with published data and precise measurement of uptaKe and clearance was possible when excluding background and blood pool activity.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 617-622 (6 pages)

Journal (Volume, Issue Number)

Nuclear Medicine Communications (Volume 20, Issue 7)

Publication milestones

  • Published - 07/1999

Publication status

Published - 07/1999

ISSN

0143-3636

Publication IDs

  • Scopus: 0032781850
  • PubMed: 10423763

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1
SciVal
Author count
5
SciVal
citations
1
SciVal
Paper percentile
29

PlumX, opens in new tab

Citation count
1
Captures
2