Skip to search boxSkip to navigationSkip to main content

Edge chipping resistance and flexural strength of polymer infiltrated ceramic network and resin nanoceramic restorative materials

*Corresponding author for this work
  • Marquette University
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Statement of problem Two novel restorative materials, a polymer infiltrated ceramic network (PICN) and a resin nanoceramic (RNC), for computer-assisted design and computer-assisted manufacturing (CAD-CAM) applications have recently become commercially available. Little independent evidence regarding their mechanical properties exists to facilitate material selection. Purpose The purpose of this in vitro study was to measure the edge chipping resistance and flexural strength of the PICN and RNC materials and compare them with 2 commonly used feldspathic ceramic (FC) and leucite reinforced glass-ceramic (LRGC) CAD-CAM materials that share the same clinical indications. Material and methods PICN, RNC, FC, and LRGC material specimens were obtained by sectioning commercially available CAD-CAM blocks. Edge chipping test specimens (n=20/material) were adhesively attached to a resin substrate before testing. Edge chips were produced using a 120-degree, sharp, conical diamond indenter mounted on a universal testing machine and positioned 0.1 to 0.7 mm horizontally from the specimen's edge. The chipping force was plotted against distance to the edge, and the data were fitted to linear and quadratic equations. One-way ANOVA determined intergroup differences (α=.05) in edge chipping toughness. Beam specimens (n=22/material) were tested for determining flexural strength using a 3-point bend test. Weibull statistics determined intergroup differences (α=.05). Flexural modulus and work of fracture were also calculated, and 1-way ANOVA determined intergroup differences (α=.05) Results Significant (P<.05) differences were found among the 4 CAD-CAM materials for the 4 mechanical properties. Specifically, the material rankings were edge chipping toughness: RNC>LRGC=FC>PICN; flexural strength: RNC=LRGC>PICN>FC; flexural modulus: RNCLRGC=PICN>FC. Conclusions The RNC material demonstrated superior performance for the mechanical properties tested compared with the other 3 materials.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 397-403 (7 pages)

Journal (Volume, Issue Number)

Journal of Prosthetic Dentistry (Volume 116, Issue 3)

Publication milestones

  • Published - 09/01/2016

Publication status

Published - 09/01/2016

ISSN

0022-3913

Publication IDs

  • Scopus: 84964978115
  • PubMed: 27157600

Publication metrics

Metrics

Fractional count
1
Fractional count
0.25
Fractional count
3
Fractional count
0.75
Fractional count
1
Fractional count
1
Scopus
citations

PlumX, opens in new tab

Captures
153
Citation count
50

Funding Details

Supported by an American Academy of Fixed Prosthodontics Stanley D. Tylman Research Grant.