Skip to search boxSkip to navigationSkip to main content

Effect of Angiotensin-Converting Enzyme Inhibitors and Receptor Blockers on Appropriate Implantable Cardiac Defibrillator Shock in Patients With Severe Systolic Heart Failure (from the GRADE Multicenter Study)

  • ,
  • Marwan M. Refaat(corresponding author)
    ,
  • Robert H. Habib
    ,
  • Laila Al-Shaar
    ,
  • Madhurmeet Singh
    ,
  • Rebecca Gutmann
*Corresponding author for this work
  • American University of Beirut
    ,
  • Outcomes Research Unit
    ,
  • University of Pittsburgh
    ,
  • University of Iowa
    ,
  • Emory University
    ,
  • Brown University
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Open access

Abstract

<p>Sudden cardiac death (SCD) is a leading cause of mortality in patients with cardiomyopathy. Although angiotensin-converting enzyme inhibitors (ACEi) and angiotensin receptor blockers (ARBs) decrease cardiac mortality in these cohorts, their role in preventing SCD has not been well established. We sought to determine whether the use of ACEi or ARB in patients with cardiomyopathy is associated with a lower incidence of appropriate implantable cardiac defibrillator (ICD) shocks in the Genetic Risk Assessment of Defibrillator Events study that included subjects with an ejection fraction of ≤30% and ICDs. Treatment with ACEi/ARB versus no-ACEi/ARB was physician dependent. There were 1,509 patients (mean age [SD] 63 [12] years, 80% men, mean [SD] EF 21% [6%]) with 1,213 (80%) on ACEi/ARB and 296 (20%) not on ACEi/ARB. We identified 574 propensity-matched patients (287 in each group). After a mean (SD) of 2.5 (1.9) years, there were 334 (22%) appropriate shocks in the entire cohort. The use of ACEi/ARB was associated with lower incidence of shocks at 1, 3, and 5 years in the matched cohort (7.7%, 16.7%, and 18.5% vs 13.2%, 27.5%, and 32.0%; RR = 0.61 [0.43 to 0.86]; p = 0.005). Among patients with glomerular filtration rate (GFR) >60 and 30 to 60 ml/min/1.73 m<sup>2</sup>, those on no-ACEi/ARB were at 45% and 77% increased risk of ICD shock compared with those on ACEi/ARB, respectively. ACEi/ARB were associated with significant lower incidence of appropriate ICD shock in patients with cardiomyopathy and GFR ≥30 ml/min/1.73 m<sup>2</sup> and with neutral effect in those with GFR <30 ml/min/1.73 m<sup>2</sup>.</p>

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 924-931 (8 pages)

Journal (Volume, Issue Number)

American Journal of Cardiology (Volume 115, Issue 7)

Publication milestones

  • Published - 04/01/2015

Publication status

Published - 04/01/2015

ISSN

0002-9149

Publication IDs

  • Scopus: 84922896893
  • PubMed: 25682436

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.07
Fractional count
14
Fractional count
0.93
Fractional count
1
Fractional count
1
SciVal
FWCI
1.37
SciVal
Author count
15
SciVal
Paper percentile
85
SciVal
citations
23

PlumX, opens in new tab

Captures
69
Citation count
39

Funding Details

This study was supported by a research grant #R01 HL77398 from the National Heart, Lung, and Blood Institute .
FunderFunding number
NHLBI
R01HL077398