Effect of normal lung definition on lung dosimetry and lung toxicity prediction in radiation therapy treatment planning
- Weili Wang,
- Yaping Xu,
- Matthew Schipper,
- Martha M. Matuszak,
- Timothy Ritter,
- Yue Cao
- China Medical University,
- Augusta University,
- Zhejiang Cancer Hospital,
- Veterans Administration,
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOpen access
Sustainable Development Goals
- SDG 3 Good Health and Well
Abstract
<p>Purpose: This study aimed to compare lung dose-volume histogram (DVH) parameters such as mean lung dose (MLD) and the lung volume receiving ≥20 Gy (V20) of commonly used definitions of normal lung in terms of tumor/target subtraction and to determine to what extent they differ in predicting radiation pneumonitis (RP). Methods and Materials: One hundred lung cancer patients treated with definitive radiation therapy were assessed. The gross tumor volume (GTV) and clinical planning target volume (PTV<sub>c</sub>) were defined by the treating physician and dosimetrist. For this study, the clinical target volume (CTV) was defined as GTV with 8-mm uniform expansion, and the PTV was defined as CTV with an 8-mm uniform expansion. Lung DVHs were generated with exclusion of targets: (1) GTV (DVH<sub>G</sub>); (2) CTV (DVH<sub>C</sub>); (3) PTV (DVH <sub>P</sub>); and (4) PTV<sub>c</sub> (DVH<sub>Pc</sub>). The lung DVHs, V20s, and MLDs from each of the 4 methods were compared, as was their significance in predicting radiation pneumonitis of grade 2 or greater (RP2). Results: There are significant differences in dosimetric parameters among the various definition methods (all Ps<.05). The mean and maximum differences in V20 are 4.4% and 12.6% (95% confidence interval 3.6%-5.1%), respectively. The mean and maximum differences in MLD are 3.3 Gy and 7.5 Gy (95% confidence interval, 1.7-4.8 Gy), respectively. MLDs of all methods are highly correlated with each other and significantly correlated with clinical RP2, although V20s are not. For RP2 prediction, on the receiver operating characteristic curve, MLD from DVH <sub>G</sub> (MLD<sub>G</sub>) has a greater area under curve of than MLD from DVH<sub>C</sub> (MLD<sub>C</sub>) or DVH<sub>P</sub> (MLD<sub>P</sub>). Limiting RP2 to 30%, the threshold is 22.4, 20.6, and 18.8 Gy, for MLD<sub>G</sub>, MLD<sub>C</sub>, and MLD<sub>P</sub>, respectively. Conclusions: The differences in MLD and V20 from various lung definitions are significant. MLD from the GTV exclusion method may be more accurate in predicting clinical significant radiation pneumonitis.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 956-963 (8 pages)Journal (Volume, Issue Number)
International Journal of Radiation Oncology Biology Physics (Volume 86, Issue 5)Publication milestones
- Published - 08/01/2013
Publication status
Published - 08/01/2013
ISSN
0360-3016Publication IDs
- Scopus: 84880029654
- PubMed: 23845844
Publication metrics
Metrics
Fractional count
1
Fractional count
0.13
Fractional count
7
Fractional count
0.88
Fractional count
1
Fractional count
1
SciVal
FWCI
0.92
SciVal
Author count
8
SciVal
citations
24
SciVal
Paper percentile
83
PlumX, opens in new tab
Captures
71
Citation count
56
Funding Details
FunderFunding number
NCI
R01CA142840