Skip to search boxSkip to navigationSkip to main content

Efficacy and biocompatibility of a photopolymerized, synthetic, absorbable hydrogel as a dural sealant in a canine craniotomy model

  • Cargill H. Alleyne
    ,
  • C. Michael Cawley
    ,
  • Daniel L. Barrow(corresponding author)
    ,
  • Bradley C. Poff
    ,
  • Michelle D. Powell
    ,
  • Amarpreet S. Sawhney
*Corresponding author for this work
  • Unknown
    ,
  • Emory University
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Object. A canine craniotomy model was used to evaluate the dural sealing efficacy and biocompatibility of a novel, synthetic, bioresorbable hydrogel. Methods. Bilateral craniotomies were performed in 24 dogs assigned to six survival periods. In each animal a parasagittal durotomy was created and then repaired. At the treatment sites the hydrogel sealant was applied over the dural repair and photopolymerized. The repair was tested for leaks to 20 cm H2O by using a Valsalva maneuver. At the control sites the incisions were sutured and tested for leaks only. After uneventful survival periods, the leak test was repeated in three of the four animals in each group. Bone-dura adhesion was evaluated, after which the dura and underlying brain were removed, fixed, and examined histologically. En bloc histological investigation was performed on a specimen obtained from the fourth animal in each group. Over a 56-day period, 18 treated sites were tested for leaks. A leak was detected at a site remote from that of the repair in one animal; this was excluded from analysis. Thus 17 of 17 treated sites remained free of leaks. On the control side of one animal, there was a leak from a new dural tear at the cranial end of the durotomy, which occurred when the bone flap was removed. This site was also excluded from analysis. Eleven of 17 leak- tested control sites remained free of leaks over the study period. Bone-dura adhesions occurred in 15 of 19 control sites and had a mean adhesion score of 1.37 (range 0-4), whereas adhesions occurred in 10 of 19 treated sites with a mean adhesion score of 0.84 (range 0-3). No cortical reaction was noted. Conclusions. This novel hydrogel sealant is efficacious in sealing rural repair sites measuring up to 2 mm. Healing of the underlying dura is not compromised and exposed cortical tissue is not altered histologically.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 308-313 (6 pages)

Journal (Volume, Issue Number)

Journal of neurosurgery (Volume 88, Issue 2)

Publication milestones

  • Published - 02/1998

Publication status

Published - 02/1998

ISSN

0022-3085

Publication IDs

  • Scopus: 2642609465
  • PubMed: 9452241

Publication metrics

Metrics

Fractional count
1
Fractional count
0.14
Fractional count
6
Fractional count
0.86
Fractional count
1
Fractional count
1
SciVal
citations
34
Scopus
citations
SciVal
FWCI
1.24
SciVal
Author count
7
SciVal
Paper percentile
80

PlumX, opens in new tab

Citation count
41
Captures
28