Objective: The purpose of this study was to determine whether anterior crowns fabricated using a computerized shade selection system (ShadeScan, Cynovad) (experimental procedure) match adjacent teeth better than anterior crowns fabricated using conventional shade prescription and clinical slides (control). Method and Materials: Five subjects who required a crown to restore a maxillary central incisor were selected. Two metal-ceramic crowns were fabricated for each incisor, 1 using the experimental procedure and 1 using the control method. The shade selection method to be used for the first and second crowns was randomly assigned. The duration of each procedure was recorded. Each restoration was tried-in in a double-blind manner and evaluated for its level of match to adjacent teeth using modified Ryge criteria. Data were analyzed within each subject using descriptive statistics and paired f test (alpha = .05). Results: In 40% of the cases, both procedures did equally well. In the remaining 60% of the cases the control procedure (two-thirds of the cases) performed better than the experimental procedure (one-third of the cases). Duration of the control procedure was 14.4 ± 5 minutes, and the experimental procedure was 5.2 ± 3.3 minutes. A paired f test showed the difference was significant (P = .0045). Conclusion: The level of matching of crowns fabricated with the ShadeScan system was not different from crowns fabricated using the control. However, it took significantly less time to record the shade with the ShadeScan system.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 793-802 (10 pages)

Journal (Volume, Issue Number)

Quintessence international (Volume 37, Issue 10)

Publication milestones

  • Published - 11/2006

Publication status

Published - 11/2006

ISSN

0033-6572

Publication IDs

  • Scopus: 33749483448
  • PubMed: 17078278

Publication metrics

Metrics

SciVal
FWCI
0.66
SciVal
Author count
4
SciVal
citations
12
SciVal
Paper percentile
64
Fractional count
1
Fractional count
0.25
Fractional count
3
Fractional count
0.75
Fractional count
1
Fractional count
1
Scopus
citations

PlumX

Captures
39
Citation count
13