Skip to search boxSkip to navigationSkip to main content

First experience with a novel robotic remote catheter system: Amigo™ mapping trial

  • Ejaz M. Khan(corresponding author)
    ,
  • William Frumkin
    ,
  • G. Andre Ng
    ,
  • Suresh Neelagaru
    ,
  • Freddy M. Abi-Samra
    ,
  • Jay Lee
*Corresponding author for this work
  • ValleyHealth
    ,
  • Lenox Hill Hospital
    ,
  • Glenfield Hospital
    ,
  • Northwest Texas Hospital
    ,
  • Ochsner Health System
    ,
  • Hoag Memorial Hospital
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Introduction: Amigo™ (Catheter Robotics, Inc., Mount Olive, NJ) remote catheter system (RCS) was designed to provide a simple and relatively inexpensive system for remote catheter manipulation. The purpose of this study was to evaluate the performance and safety of Amigo in mapping the right side of the heart. Methods and results: This non-randomized, prospective clinical trial was conducted at 13 sites (NCT: #01139814). Using the controller, a mapping catheter was moved to eight pre-specified locations in a specific sequence: right ventricular apex, mid-right ventricular septum, right ventricular outflow tract, His-bundle position, coronary sinus ostium, high right atrium, lateral tricuspid annulus, and low lateral right atrium. The pre-specified efficacy endpoint was to achieve 80 % successful navigation to all locations. Time to each location, location accuracy, and quality of contact were confirmed by imaging and specific criteria for electrograms and pacing thresholds. In 181 patients, a total of 1,396 of 1,448 (96 %) locations were successfully mapped with all protocol criteria met (one-sided p value < 0.0001). The median time to move the catheter to a new location was 24 s. The Amigo-related major complication rate was 0 % which was significantly less than the predefined endpoint of 4 % (one-sided p = 0.003). Conclusion: We found the Amigo RCS to be safe and effective for positioning a mapping catheter at sites within the right atrium and ventricle.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 121-129 (9 pages)

Journal (Volume, Issue Number)

Journal of Interventional Cardiac Electrophysiology (Volume 37, Issue 2)

Publication milestones

  • Published - 08/2013

Publication status

Published - 08/2013

ISSN

1383-875X

Publication IDs

  • Scopus: 84879984434
  • PubMed: 23636870

Publication metrics

Metrics

Scopus
citations
Fractional count
1
Fractional count
0.08
Fractional count
12
Fractional count
0.92
Fractional count
1
Fractional count
1
SciVal
FWCI
2.06
SciVal
Author count
13
SciVal
citations
84
SciVal
Paper percentile
97
SciVal
Top percentile
5

PlumX, opens in new tab

Citation count
153
Captures
112