Heat generation during removal of an abutment screw fragment from dental implants
- Sergio R. Arias,
- ,
- Donald Mettenburg,
- Mohamed Sharawy,
- Stephen Looney,
- Private Practice,
- ,
- Augusta University,
- ,
- ,
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewAbstract
<p>Statement of problem: Little information is available on the effect of drilling speed on surrounding bone during the removal of an abutment screw fragment. Purpose: The purpose of this in vitro study was to compare, in vitro, the peak temperature increase during the removal of fractured abutment screws from implants placed in a porcine mandible, using drilling speeds of 600 or 2000 rpm. Material and methods: Twenty 4.3×13-mm dental implants were placed in 10 dissected porcine mandibles: 2 implants per mandible, 1 on each side. Localized defects were created in 20 surface-treated abutment screws, which were then tightened into each implant until a reproducible fracture occurred in each screw. The fractured screws were removed with a handpiece removal kit and irrigated with room-temperature water at either 600 or 2000 rpm. The temperature rise at the implant surface was measured at 3 levels with 3 type-K thermocouples. Repeated measure ANOVA was performed with the Tukey-Kramer post hoc test for mean pair-wise comparisons (α=.05 for all tests). Results: Mean peak temperatures were significantly higher at 2000 rpm than at 600 rpm in the mid-body (P<.001) and crestal (P=.003) regions but not in the apical (P=.225) implant locations. No significant differences in mean peak temperatures were found among the 3 locations using 600 rpm (P=.179). In the 2000-rpm group, mean peak temperature in the mid-body area was consistently higher than that in the apical (P<.001) area, and more instances of temperature rise above 56°C and 60°C were observed. In 1 implant from this group, the estimated peak temperature exceeded the bone damage threshold value (50°C for 30 seconds). Conclusions: A drilling speed of 2000 rpm during the removal of abutment screw fragments caused overheating of the outer surface of the implant which may damage the surrounding bone; a speed of 600 rpm appears to be safe.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 620-625 (6 pages)Journal (Volume, Issue Number)
Journal of Prosthetic Dentistry (Volume 119, Issue 4)Publication milestones
- Accepted/In press - 2017
- Published - 04/2018
Publication status
Published - 04/2018
ISSN
0022-3913Publication IDs
- Scopus: 85030025931
- PubMed: 28967404
- ORCID: /0000-0003-1947-3337/work/54796713
Publication metrics
Metrics
SciVal
FWCI
0.17
SciVal
Author count
7
SciVal
citations
1
SciVal
Paper percentile
40
Fractional count
5
Fractional count
0.71
Fractional count
2
Fractional count
0.29
Fractional count
5
Fractional count
1
PlumX, opens in new tab
Captures
50
Citation count
8