Skip to search boxSkip to navigationSkip to main content

Histologic evaluation of implants following flapless and flapped surgery: A study in canines

  • William Becker(corresponding author)
    ,
  • Ulf M E Wikesjö
    ,
  • Lars Sennerby
    ,
  • Mohammed Qahash
    ,
  • Philippe Hujoel
    ,
  • Moshe Goldstein
*Corresponding author for this work
  • University of Washington
    ,
  • ,
  • University of Gothenburg
    ,
  • Medical College of Georgia
    ,
  • Hebrew University of Jerusalem
    ,
  • The Hebrew University
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Background: Flapless surgery requires penetration of the alveolar mucosa and bone without reflection of mucoperiosteal flaps. Do these techniques force gingival tissue or foreign materials into osteotomies? If so, do such tissues or materials interfere with osseointegration? A proof-of-principle study using a canine model attempted to answer these questions. Methods: Five young adult Hound Labrador mongrel dogs received implants with a moderately roughened surface by anodic oxidation using flapless or conventional one-stage (control) surgery in contralateral jaw quadrants. The implants were placed into the osteotomies, and the international stability quotient (ISQ) was recorded using resonance frequency analysis. These measurements were repeated following a 3-month healing interval when the animals were euthanized, and implants and surrounding tissues were retrieved and processed for histologic analysis. Results: The implants were stable upon insertion and demonstrated increased stability at 3 months without significant differences between surgical protocols. The histologic evaluation showed high bone-implant contact (flapless surgery: 54.7% ± 8.4%; control: 52.2% ± 13.0%; P >0.05) without evidence of gingival tissue or foreign body inclusions. There were no significant differences in marginal bone levels between the surgical protocols. Post-insertion and at 3 months, ISQ values depended on the amount of torque delivered. Immediately post-insertion, for every 1-unit increase in torque value, the ISQ increased by 0.3 (95% confidence interval: 0.1 to 0.4; P = 0.0043). Three months postoperatively, for every one-unit increase in torque the ISQ value decreased 0.2 (95% confidence interval: -0.4 to -0.1; P = 0.00 12). The effect of torque on ISQ values was independent of treatment effects and remained significant after adjustment for treatment. Conclusions: The results suggest that implants placed without flap reflection remain stable and exhibit clinically relevant osseointegration similar to when implants are placed with flapped procedures. Greater torque at implant placement resulted in less implant stability at 3 months.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 1717-1722 (6 pages)

Journal (Volume, Issue Number)

Journal of periodontology (Volume 77, Issue 10)

Publication milestones

  • Published - 10/2006

Publication status

Published - 10/2006

ISSN

0022-3492

Publication IDs

  • Scopus: 33750589187
  • PubMed: 17032115

Publication metrics

Metrics

SciVal
citations
62
Scopus
citations
SciVal
FWCI
1.68
SciVal
Author count
7
SciVal
Paper percentile
90
SciVal
Top percentile
10
Fractional count
1
Fractional count
0.14
Fractional count
6
Fractional count
0.86
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
92
Citation count
69