Skip to search boxSkip to navigationSkip to main content

Image-guided ex-vivo targeting accuracy using a laparoscopic tissue localization system

  • Jerry Bieszczad
    ,
  • Eric Friets
    ,
  • Darin Knaus
    ,
  • Thomas Rauth
    ,
  • Alan Herline
    ,
  • Michael Miga
  • Creare Incorporated
    ,
  • Vanderbilt University
Scholary Output:
Chapter in Book/Report/Conference proceeding
Conference contribution

Related Event

Title

Medical Imaging 2007: Visualization and Image-Guided Procedures

Event type

Other

Date

02/18/2007 - 02/20/2007

Location

San Diego, CAUnited States

Abstract

In image-guided surgery, discrete fiducials are used to determine a spatial registration between the location of surgical tools in the operating theater and the location of targeted subsurface lesions and critical anatomic features depicted in preoperative tomographic image data. However, the lack of readily localized anatomic landmarks has greatly hindered the use of image-guided surgery in minimally invasive abdominal procedures. To address these needs, we have previously described a laser-based system for localization of internal surface anatomy using conventional laparoscopes. During a procedure, this system generates a digitized, three-dimensional representation of visible anatomic surfaces in the abdominal cavity. This paper presents the results of an experiment utilizing an ex-vivo bovine liver to assess subsurface targeting accuracy achieved using our system. During the experiment, several radiopaque targets were inserted into the liver parenchyma. The location of each target was recorded using an optically-tracked insertion probe. The liver surface was digitized using our system, and registered with the liver surface extracted from post-procedure CT images. This surface-based registration was then used to transform the position of the inserted targets into the CT image volume. The target registration error (TRE) achieved using our surface-based registration (given a suitable registration algorithm initialization) was 2.4 mm ± 1.0 mm. A comparable TRE (2.6 mm ± 1.7 mm) was obtained using a registration based on traditional fiducial markers placed on the surface of the same liver. These results indicate the potential of fiducial-free, surface-to-surface registration for image-guided lesion targeting in minimally invasive abdominal surgery.

Publication Information

Output type

Scholary Output:
Chapter in Book/Report/Conference proceeding
Conference contribution

Host publication Subtitle

Visualization and Image-Guided Procedures

Original language

English (US)

Article number

65091A

Publication milestones

  • Published - 2007

Publication status

Published - 2007

Edition

PART 1

Publication series

  • Publication series name: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
    ISSN (Print): 1605-7422
    Volume: 6509
    Number: PART 1
0819466271, 9780819466273

Publication IDs

  • Scopus: 35148900090

Host publication title

Medical Imaging 2007

Publication metrics

Metrics

SciVal
Author count
8
SciVal
Paper percentile
25
Fractional count
1
Fractional count
0.13
Fractional count
7
Fractional count
0.88
Fractional count
1
Fractional count
1