Impact of ischemia on left ventricular dyssynchrony by phase analysis of gated single photon emission computed tomography myocardial perfusion imaging

  • Wael Aljaroudi(corresponding author)
    ,
  • Jayanth Koneru
    ,
  • Jaekyeong Heo
    ,
  • Ami E. Iskandrian
*Corresponding author for this work
  • Cleveland Clinic Foundation
    ,
  • University of Alabama at Birmingham
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Background: There is increasing awareness of the value of phase analysis of gated tomographic myocardial perfusion imaging in assessing left ventricular (LV) dyssynchrony. A concern repeatedly raised in many studies is whether reversible defects in the stress images "ischemia" could affect the phase-derived standard deviation and bandwidth, the two commonly used dyssynchrony indices. We hypothesized that the stress and rest images should provide comparable information because the images are acquired 1 hour after the tracer injection. Methods and Results: We studied two groups of patients with normal LV ejection fraction and no fixed perfusion defects. In group-1 (N = 20), the patients had reversible perfusion defects involving > 10% of the LV myocardium and in group-2 (N = 20), the patients had normal images. All patients underwent stress/rest-gated single photon emission computed tomography sestamibi imaging (the stress study was acquired with the lower dose) between January and March 2010. Patients with left bundle branch block or ventricular pacing were excluded. The patients in group-1 had a mean age of 61 ± 9 years, 65% were men, 75% Caucasians, and 70% had known prior coronary artery disease. The size of the reversible perfusion defect was 20 ± 13% (range 11%-50%) of the LV myocardium. The rest and stress phase-derived standard deviation (16 ± 6° vs 18 ± 8° and 16 ± 7° vs. 19 ± 6°) and the rest and stress bandwidth (42 ± 14° vs 46 ± 16° and 45 ± 17° vs 52 ± 12°), respectively, (P = NS for all) were similar in the two groups. The change (stress-rest) in standard deviation and bandwidth in groups 1 and 2 were not statistically significant (0.2 ± 3.1° vs 1.4 ± 4.7°, and 2 ± 13° vs 5 ± 13°, respectively, P = NS). There was no significant change from rest to stress in the standard deviation and the bandwidth in group-1 (P = .8 and .4, respectively) and group-2 (P = .2 and .08, respectively). There was no correlation between the size of the reversible perfusion defect and the change in phase standard deviation or bandwidth (r = 0.07 and 0.12, respectively, P = NS). Conclusions: The presence of even a large reversible perfusion defect does not alter the indices of mechanical dyssynchrony by phase analysis. Further, comparable information is obtained whether using a low dose or a high dose of the radiotracer.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 36-42 (7 pages)

Journal (Volume, Issue Number)

Journal of Nuclear Cardiology (Volume 18, Issue 1)

Publication milestones

  • Published - 02/2011

Publication status

Published - 02/2011

ISSN

1071-3581

Publication IDs

  • Scopus: 79951676360
  • PubMed: 21104361

Publication metrics

Metrics

SciVal
citations
60
SciVal
FWCI
3.35
SciVal
Author count
4
SciVal
Paper percentile
93
SciVal
Top percentile
10
Scopus
citations
Fractional count
1
Fractional count
0.25
Fractional count
3
Fractional count
0.75
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
33
Citation count
72