Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: Results of the adaptive CRT trial
- David O. Martin(corresponding author),
- Bernd Lemke,
- David Birnie,
- Henry Krum,
- Kathy Lai Fun Lee,
- Kazutaka Aonuma
- Cleveland Clinic Foundation,
- Klinikum Lüdenscheid,
- University of Ottawa,
- Monash University,
- The University of Hong Kong,
- University of Tsukuba
Abstract
Background: In patients with sinus rhythm and normal atrioventricular conduction, pacing only the left ventricle with appropriate atrioventricular delays can result in superior left ventricular and right ventricular function compared with standard biventricular (BiV) pacing. Objective: To evaluate a novel adaptive cardiac resynchronization therapy ((aCRT) algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular or BiV pacing with dynamic optimization of atrioventricular and interventricular delays. Methods: Patients (n = 522) indicated for a CRT-defibrillator were randomized to aCRT vs echo-optimized BiV pacing (Echo) in a 2:1 ratio and followed at 1-, 3-, and 6-month postrandomization. Results: The study met all 3 noninferiority primary objectives: (1) the percentage of aCRT patients who improved in their clinical composite score at 6 months was at least as high in the aCRT arm as in the Echo arm (73.6% vs 72.5%, with a noninferiority margin of 12%; P =.0007); (2) aCRT and echo-optimized settings resulted in similar cardiac performance, as demonstrated by a high concordance correlation coefficient between aortic velocity time integrals at aCRT and Echo settings at randomization (concordance correlation coefficient = 0.93; 95% confidence interval 0.91-0.94) and at 6-month postrandomization (concordance correlation coefficient = 0.90; 95% confidence interval 0.87-0.92); and (3) aCRT did not result in inappropriate device settings. There were no significant differences between the arms with respect to heart failure events or ventricular arrhythmia episodes. Secondary end points showed similar benefit, and right-ventricular pacing was reduced by 44% in the aCRT arm. Conclusions: The aCRT algorithm is safe and at least as effective as BiV pacing with comprehensive echocardiographic optimization.
Publication Information
Output type
Original language
English (US)Pages from-to (Number of pages)
Pages 1807-1814.e1Journal (Volume, Issue Number)
Heart Rhythm (Volume 9, Issue 11)Publication milestones
- Published - 11/01/2012
Publication status
ISSN
1547-5271Publication IDs
- Scopus: 84867859165
- PubMed: 22796472