Loop and knot security of a novel arthroscopic sliding-locking knot using high-strength sutures
- CPT Sally Corey(corresponding author),
- Karl Wenger,
- CPT Peter Johnson,
- United States Army
Scholary Output:
Contribution to journal
Article
Peer-reviewAbstract
Objective: We evaluated the loop and knot security of a novel arthroscopic knot, the Wiese knot, using different types of sutures. Methods: The Wiese knot was tied using four different brands of braided sutures (Ethibond, Orthocord, FiberWire, and UltraBraid) with and without a series of three reversing half-hitches (RHAPs) and tested for loop and knot security. Results: Orthocord provided the greatest amount of loop security. FiberWire delivered the highest knot security. UltraBraid had the greatest ultimate force. Three half-hitches increased the maximal load to clinical failure. Conclusion: The biomechanical characteristics of the Wiese knot are affected by suture material qualities.
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 980-983 (4 pages)Journal (Volume, Issue Number)
Journal of Orthopaedics (Volume 15, Issue 4)Publication milestones
- Published - 12/2018
Publication status
Published - 12/2018
Publication IDs
- Scopus: 85054154785
Publication metrics
Metrics
SciVal
Author count
4
SciVal
Paper percentile
27
Fractional count
1
Fractional count
0.25
Fractional count
3
Fractional count
0.75
Fractional count
1
Fractional count
1
PlumX, opens in new tab
Citation count
6
Captures
11