Skip to search boxSkip to navigationSkip to main content

Multiplexed quantitation of endogenous estrogens and estrogen metabolites in human peritoneal fluid

  • Xia Xu
    ,
  • Essam El Dine R. Othman
    ,
  • Haleem J. Issaq
    ,
  • Daniela Hornung
    ,
  • Ayman Al-Hendy
    ,
  • Timothy D. Veenstra(corresponding author)
*Corresponding author for this work
  • SAIC
    ,
  • University of Texas Medical Branch at Galveston
    ,
  • Assiut University
    ,
  • Universitätsklinikum Schleswig-Holstein Campus Lübeck
Scholary Output:
Contribution to journal
Article
Peer-review

Open access

Sustainable Development Goals

  • SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well

Abstract

Endogenous estrogens and estrogen metabolites (EM) in human peritoneal fluid may play an important role in health and disease, yet little is known regarding their types and levels present in human peritoneal fluid, primarily due to the lack of an analytical method that is capable of directly quantifying their absolute abundances. In this report, we describe the application of a capillary LC-MS/MS method for identifying and quantifying biologically active and total endogenous EM in human peritoneal fluid. The method requires only 50 μL of peritoneal fluid, yet can quantify 13 distinct EM. Calibration curves for each EM were linear over a 103-fold concentration range and the lower LOQ was 50 fg on-column. For charcoal stripped human peritoneal fluid sample containing 10 pg/mL of each EM, accuracy ranged from 83 to 118%, and intrabatch precision ranged from 0.2 to 4.4% RSD and interbatch precision ranged from 5.5 to 15.5% RSD. The analyses of human female peritoneal fluid shows that at least 10 biologically active and 11 total endogenous EM can be positively identified and quantitatively measured. Many of the biologically active forms are present in high abundance and possess distinct biological activities which warrant further study. Although micellar EKC gave baseline separation of a standard mixture of 10 EM, the LOQs using UV detection were not suitable for the assay of the low level estrogens in biological samples.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 2706-2713 (8 pages)

Journal (Volume, Issue Number)

ELECTROPHORESIS (Volume 29, Issue 12)

Publication milestones

  • Published - 06/2008

Publication status

Published - 06/2008

ISSN

0173-0835

Publication IDs

  • Scopus: 46249112359
  • PubMed: 18512681

Publication metrics

Metrics

SciVal
FWCI
0.23
SciVal
Author count
6
SciVal
citations
6
SciVal
Paper percentile
53
Scopus
citations
Fractional count
1
Fractional count
0.17
Fractional count
5
Fractional count
0.83
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Usage
1
Citation count
8
Captures
7

Funding Details

FunderFunding number
NICHD
R01HD046228