Optimized energy of spectral CT for infarct imaging: Experimental validation with human validation
- Veit Sandfort,
- Srikanth Palanisamy,
- Rolf Symons,
- Amir Pourmorteza,
- Mark A. Ahlman,
- Kelly Rice
- National Institutes of Health,
- National Institutes of Health, Bethesda,
- Siemens,
- Johns Hopkins University
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOpen access
Abstract
<p>Objectives Late contrast enhancement visualizes myocardial infarction, but the contrast to noise ratio (CNR) is low using conventional CT. The aim of this study was to determine if spectral CT can improve imaging of myocardial infarction. Materials and Methods A canine model of myocardial infarction was produced in 8 animals (90-min occlusion, reperfusion). Later, imaging was performed after contrast injection using CT at 90 kVp/150 kVpSn. The following reconstructions were evaluated: Single energy 90 kVp, mixed, iodine map, multiple monoenergetic conventional and monoenergetic noise optimized reconstructions. Regions of interest were measured in infarct and remote regions to calculate contrast to noise ratio (CNR) and Bhattacharya distance (a metric of the differentiation between regions). Blinded assessment of image quality was performed. The same reconstruction methods were applied to CT scans of four patients with known infarcts. Results For animal studies, the highest CNR for infarct vs. myocardium was achieved in the lowest keV (40 keV) VMo images (CNR 4.42, IQR 3.64–5.53), which was superior to 90 kVp, mixed and iodine map (p = 0.008, p = 0.002, p < 0.001, respectively). Compared to 90 kVp and iodine map, the 40 keV VMo reconstructions showed significantly higher histogram separation (p = 0.042 and p < 0.0001, respectively). The VMo reconstructions showed the highest rate of excellent quality scores. A similar pattern was seen in human studies, with CNRs for infarct maximized at the lowest keV optimized reconstruction (CNR 4.44, IQR 2.86–5.94). Conclusions Dual energy in conjunction with noise-optimized monoenergetic post-processing improves CNR of myocardial infarct delineation by approximately 20–25%.</p>
Publication Information
Output type
Scholary Output:
Contribution to journal
Article
Research
Peer-reviewOriginal language
English (US)Pages from-to (Number of pages)
Pages 171-178 (8 pages)Journal (Volume, Issue Number)
Journal of Cardiovascular Computed Tomography (Volume 11, Issue 3)Publication milestones
- Published - 05/2017
Publication status
Published - 05/2017
ISSN
1934-5925Publication IDs
- Scopus: 85013042383
- PubMed: 28229910
Publication metrics
Metrics
Fractional count
1
Fractional count
0.08
Fractional count
12
Fractional count
0.92
Fractional count
1
Fractional count
1
PlumX, opens in new tab
Captures
44
Citation count
20
Funding Details
FunderFunding number
NIBIB
ZIAEB000072