Skip to search boxSkip to navigationSkip to main content

Penetration of fluids into peridontal pockets using a powered toothebrush/irrigator device

  • Martha Goel Brackett(corresponding author)
    ,
  • Connie L. Drisko
    ,
  • Ana L. Thompson
    ,
  • Jennifer L. Waller
    ,
  • Donna L. Marshall
    ,
  • George S. Schuster
*Corresponding author for this work
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Abstract

This study was a single-blind, randomized, controlled clinical trial. The researchers evaluated a powered brush/irrigating device (HydraBrush Oral Health System™; OHS) for its safety and ability to deliver a solution to the bottom of 5-6 mm pockets, compared to rinsing alone with a solution following brushing with a powered toothbrush (Sonicare Elite™ 7800; SE). An evaluation technique to measure the quantity and quality of solution able to enter the pocket was also introduced in this project. Methods: Subjects were randomized in one of two-groups: brush plus simultaneous irrigation (OHS) versus brush plus rinsing (SE). Subjects used their devices at home for two weeks. At the measurement visit, subjects used the OHS to irrigate and brush simultaneously for 1 minute (30 seconds per each side of the mouth) with a 0.01% erythrosine disclosing solution in 10 oz of distilled water. Control subjects brushed for 2 minutes with a SE followed by a 1 minute rinse with an identical disclosing solution. A blinded evaluator collected six samples of approximately of 1 μL of sucular fluid from six 5-6 mm evaluation sites. This was accomplished by inserting a microcapillary tip with a 20 μL micropipette in the sulcus. Two-group repeated measures ANOVA was used to examine differences in two measures of the disclosing solution between OHS and SE subjects; the spectrometer reading of the disclosing solutions, and by visual inspection of the samples (positive/negative) to determine the presence or absence of solution in the samples. Subjects' diaries were collected. Bleeding and discomfort during the evaluation period was reported. Results: Visually, OHS had a significantly greater proportion of solution taken from the base of 5-6 mm sites than the SE (p=0.0001). However, there was no statistical difference between the two groups (p=.1359) in the spectrophotometer readings. Conclusion: The experimental device is more efficient in delivering a solution to the base of 5-6 mm pockets than rinsing following use of a control powered toothbrush. Both devices have demonstrated they are safe and well accepted by patients. The technique developed provides a useful method for quantitative and qualitative studies of solutions from the base of periodontal pockets.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 30-39 (10 pages)

Journal (Volume, Issue Number)

Journal of Contemporary Dental Practice (Volume 7, Issue 3)

Publication milestones

  • Published - 07/01/2006

Publication status

Published - 07/01/2006

ISSN

1526-3711

Publication IDs

  • Scopus: 33746501525
  • PubMed: 16820805
  • ORCID: /0000-0003-4066-4541/work/68027289

Publication metrics

Metrics

SciVal
citations
3
Fractional count
3
Fractional count
0.50
Fractional count
3
Fractional count
0.50
Fractional count
3
Fractional count
1
SciVal
FWCI
0.22
SciVal
Author count
6
SciVal
Paper percentile
44
Scopus
citations

PlumX

Citation count
4