Skip to search boxSkip to navigationSkip to main content

Perfusion MR imaging with a superparamagnetic iron oxide using T2- weighted and susceptibility-sensitive echoplanar sequences: Evaluation of tumor vascularity in hepatocellular carcinoma

  • Tomoaki Ichikawa(corresponding author)
    ,
  • ,
  • Tsutomu Araki
    ,
  • Keiji Touyama
    ,
  • Hiroki Haradome
    ,
  • Junichi Hachiya
*Corresponding author for this work
  • University of Yamanashi
    ,
  • Kyorin University
Scholary Output:
Contribution to journal
Article
Research
Peer-review

Abstract

OBJECTIVE. The study purpose was to examine the usefulness of perfusion echoplanar MR imaging with a superparamagnetic iron oxide (SHU-555A) for evaluating the vascularity of hepatocellular carcinomas. SUBJECTS AND METHODS. Twenty-two patients with 32 hepatocellular carcinomas underwent perfusion imaging with bolus injection (0.7-1.1 ml) of SHU-555A. Echoplanar sequences included multishot spin-echo (17 patients) and single-shot gradient-echo (five patients) imaging. Image acquisition was repeated every 30 sec for 3 min with the multishot spin-echo sequence and every 2 sec for 100 sec with the single-shot gradient-echo sequence. Lesion signal intensity versus time curves were created for quantitative analysis. RESULTS. Transient decreases in tumor signal intensity (28.8% with multishot spin-echo and 63.3% with the single-shot gradient-echo) were seen in the perfusion phase. These decreases in signal intensity were statistically significantly (p < .01) different for each histologic type of hepatocellular carcinoma (poorly differentiated, 43.3%; well differentiated, 18.4%; and moderately differentiated, 24.8%). After the perfusion phase, the tumor signal intensities rapidly recovered. The multishot spin-echo sequence could detect some signal changes even in lesions smaller than 1 cm. CONCLUSION. Hepatocellular carcinoma vascularity can be evaluated with perfusion echoplanar imaging with SHU-555A. Because of its excellent temporal resolution, the singleshot gradient-echo echoplanar sequence detects the transient signal decrease in most lesions. The high image quality of the multishot spin-echo echoplanar sequence allows evaluation of the vascularity of even very small lesions.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Research
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 207-213 (7 pages)

Journal (Volume, Issue Number)

American Journal of Roentgenology (Volume 173, Issue 1)

Publication milestones

  • Published - 07/1999

Publication status

Published - 07/1999

ISSN

0361-803X

Publication IDs

  • Scopus: 0032965593
  • PubMed: 10397128

Publication metrics

Metrics

Scopus
citations
SciVal
FWCI
1.61
SciVal
Author count
9
SciVal
citations
40
SciVal
Paper percentile
82
Fractional count
1
Fractional count
0.11
Fractional count
8
Fractional count
0.89
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
15
Citation count
39