Skip to search boxSkip to navigationSkip to main content

Precision of fit of implant-supported screw-retained 10-unit computer-aided-designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: An in vitro study

  • Joannis Katsoulis(corresponding author)
    ,
  • Regina Mericske-Stern
    ,
  • Lolita Rotkina
    ,
  • Christoph Zbären
    ,
  • Norbert Enkling
    ,
  • Markus B. Blatz
*Corresponding author for this work
  • University of Bern
    ,
  • University of Pennsylvania
    ,
  • RAS - Ioffe Physico Technical Institute
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Objective: To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. Materials and methods: Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera™) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. Results: No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). Conclusions: Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 165-174 (10 pages)

Journal (Volume, Issue Number)

Clinical Oral Implants Research (Volume 25, Issue 2)

Publication milestones

  • Published - 02/2014

Publication status

Published - 02/2014

ISSN

0905-7161

Publication IDs

  • Scopus: 84892373714
  • PubMed: 23025489

Publication metrics

Metrics

Scopus
citations
SciVal
FWCI
5.82
SciVal
Author count
6
SciVal
citations
63
SciVal
Paper percentile
96
SciVal
Top percentile
5
Fractional count
1
Fractional count
0.17
Fractional count
5
Fractional count
0.83
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Citation count
103
Captures
127