Skip to search boxSkip to navigationSkip to main content

Radioimaging of implants in rats using Tc-99m-MDP

  • Michael McCracken(corresponding author)
    ,
  • Kurt Zinn
    ,
  • Jack E. Lemons
    ,
  • John A. Thompson
    ,
  • Dale Feldman
*Corresponding author for this work
  • University of Alabama at Birmingham
Scholary Output:
Contribution to journal
Article
Peer-review

Abstract

Radiopharmaceutical isotopes are widely used clinically to detect tumors of osteogenic origin. One example is Technetium-99m methylene diphosphonate (Tc-99m-MDP). When viewed with a gamma camera, the concentration of the isotope (increased gamma activity) indicates an area of increased bone activity. This technology provides an opportunity to measure bone growth around implants In vivo. The purpose of this study was to measure Tc-99m-MDP activity around titanium alloy implants placed in the tibiae of rats. Some implant sites were treated with a growth factor; other sites served as controls. The hypothesis tested was that implants placed with a growth factor would have greater associated Tc-99m-MDP activity. Twelve adult male Sprague-Dawley rats were anesthetized and surgical access to the medial proximal tibiae was obtained. Titanium alloy screw implants were placed in six animals along with 65 μg of acidic fibroblast growth factor (FGF-1); the other six animals received implants only and served as controls. After five days, rats were injected with 1500 μCi of Tc-99m-MDP. After 3 hours, rats were imaged with a gamma camera. The Tc-99m-MDP intensity associated with each implant was quantified and the means for each group were compared using ANOVA. Implants treated with FGF-1 demonstrated significantly more Tc-99m-MDP activity than implants alone. This suggests that Tc-99m-MDP analysis may be a useful tool for determining bone growth around implants in laboratory animals in vivo.

Publication Information

Output type

Scholary Output:
Contribution to journal
Article
Peer-review

Original language

English (US)

Pages from-to (Number of pages)

Pages 372-378 (7 pages)

Journal (Volume, Issue Number)

Clinical Oral Implants Research (Volume 12, Issue 4)

Publication milestones

  • Published - 2001

Publication status

Published - 2001

ISSN

0905-7161

Publication IDs

  • Scopus: 0035434649
  • PubMed: 11488867

Publication metrics

Metrics

Scopus
citations
SciVal
FWCI
1.08
SciVal
Author count
5
SciVal
citations
19
SciVal
Paper percentile
69
Fractional count
1
Fractional count
0.20
Fractional count
4
Fractional count
0.80
Fractional count
1
Fractional count
1

PlumX, opens in new tab

Captures
25
Citation count
12